Technisches Datenblatt / Technical datasheet: PW 6207 D
Datum / Date: 24.04.2013
Seite / Page:
8
Machine connections:
Electrical
connection
1. Standard voltage (standard version)
V
3N AC 380 - 415
Frequency
Hz
50 - 60
Connected load
kW
4.3
Fuse rating
A
3 × 16
Connection cable, min. gauge
mm²
5 × 1.5
Connection cable not supplied (to be ordered
separately)
Variations in the following countries:
1. Standard voltage (standard version)
V
3 AC 220 - 240
Frequency
Hz
60
Connected load
kW
4.3
Fuse rating
A
3 × 15
Connection cable, min. gauge
mm²
4 × 1.5
Connection cable not supplied (to be ordered
separately)
Alternative voltage (convertible)
V
3 AC 208
Frequency
Hz
60
Connected load
kW
4.3
Fuse rating
A
3 × 15
Connection cable, min. gauge
mm²
4 × 1.5
Connection cable not supplied (to be ordered
separately)
The electrical connection may only be made to an electrical
system provided in accordance with all appropriate local and
national legislation and regulations. In addition, all regulations
of the appropriate utility supply companies and standards
relating to safety, and all applicable valid regulations and
technical standards must be complied with!
Electrical connection is the responsibility of a qualified
electrician.
The machine can be either hard-wired or connected via a
socket in compliance with IEC 60309-1. Wall socket or mains
isolator must be accessible after installation.
It is always recommended to make electrical connection via a
plug and socket so that electrical safety checks, e.g. during
repair or service work, can be carried out easily.
If it is necessary to install a residual current device (RCD) in
accordance with the local regulations, a residual current
device type B must be used.
Equipotential
bonding
Connection with male thread
mm
10 × 35
for washers and nuts
M
10
Fasteners such as washers and nuts are not provided.
If necessary, equipotential bonding with good galvanic
contact must be guaranteed in compliance with all applicable
local and national installation codes.
Steam
connection
Steam pressure (Low pressure steam)
kPa
50
Direct
Boiling point
°C
120
Mass flow (max. delivery)
kg/h
22
Heater rating
kW
13
Steam pressure (high-pressure steam)
kPa
50 - 400
Boiling point
°C
152
Mass flow (max. delivery)
kg/h
52
Heater rating
kW
30
On-site threaded union
Inch
½" female thread
Steam valve, filter, non-return valve and steam shut-off valve
must be provided on site.
The steam valve should be installed in such a way as to
prevent any wash liquor from the machine from flowing back
into the valve.