Technisches Datenblatt / Technical datasheet: PW 6207 D 

Datum / Date: 24.04.2013 

  Seite / Page: 

8

 

 

 

Machine connections: 

 

Electrical 

connection 

1. Standard voltage (standard version) 

 

3N AC 380 - 415  

 

Frequency 

 

Hz 

50 - 60 

 

Connected load 

 

kW 

4.3 

 

Fuse rating 

 

3 × 16 

 

 

Connection cable, min. gauge 

 

mm² 

5 × 1.5 

 

 

Connection cable not supplied (to be ordered 
separately) 

 

 

 

 

Variations in the following countries: 

 

 

1. Standard voltage (standard version) 

 

3 AC 220 - 240 

 

Frequency 

 

Hz 

60 

 

Connected load 

 

kW 

4.3 

 

 

Fuse rating 

 

3 × 15 

 

 

Connection cable, min. gauge 

 

mm² 

4 × 1.5 

 

 

Connection cable not supplied (to be ordered 
separately) 

 

 

 

 

 

Alternative voltage (convertible) 

 

3 AC 208 

 

Frequency 

 

Hz 

60 

 

Connected load 

 

kW 

4.3 

 

 

Fuse rating 

 

3 × 15 

 

 

Connection cable, min. gauge 

 

mm² 

4 × 1.5 

 

 

Connection cable not supplied (to be ordered 
separately) 

 

 

 

 

 

The electrical connection may only be made to an electrical 
system provided in accordance with all appropriate local and 
national legislation and regulations. In addition, all regulations 
of the appropriate utility supply companies and standards 
relating to safety, and all applicable valid regulations and 
technical standards must be complied with! 

Electrical connection is the responsibility of a qualified 
electrician. 

The machine can be either hard-wired or connected via a 
socket in compliance with IEC 60309-1. Wall socket or mains 
isolator must be accessible after installation. 

It is always recommended to make electrical connection via a 
plug and socket so that electrical safety checks, e.g. during 
repair or service work, can be carried out easily. 

If it is necessary to install a residual current device (RCD) in 
accordance with the local regulations, a residual current 
device type B must be used. 

 

 

 

Equipotential 

bonding 

Connection with male thread 

mm 

10 × 35 

for washers and nuts 

M  

10 

Fasteners such as washers and nuts are not provided. 

 

 

If necessary, equipotential bonding with good galvanic 
contact must be guaranteed in compliance with all applicable 
local and national installation codes. 

 

 

 

Steam 
connection 

Steam pressure (Low pressure steam) 

kPa 

 50 

Direct 

Boiling point 

°C 

 120 

 

Mass flow (max. delivery) 

kg/h 

22 

 

 

Heater rating 

kW 

13 

 

 

Steam pressure (high-pressure steam) 

kPa 

50 - 400 

 

 

Boiling point 

°C 

 152 

 

 

Mass flow (max. delivery) 

kg/h 

52 

 

 

Heater rating 

kW 

30 

 

 

On-site threaded union 

Inch 

½" female thread 

 

 

Steam valve, filter, non-return valve and steam shut-off valve 
must be provided on site. 

 

 

 

 

The steam valve should be installed in such a way as to 
prevent any wash liquor from the machine from flowing back 
into the valve. 

 

 

 
 

 

Содержание PW 6137 D

Страница 1: ...06 15 M Nr 10 303 290 01 Installation plan Washer extractor PW 6207 D en GB ...

Страница 2: ...M Nr 10 303 290 01 2 ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...mm 240 Width mm 920 Depth mm 1019 BS Concrete platform Recommended height mm 240 Minimum height mm 100 Plinth width min mm 920 Min plinth depth mm 1050 DAV Steam connection valve The steam connection valve to regulate the steam supply must be provided on site The following valves can be ordered separately as electric steam valves or as pneumatic steam valves Electric steam valve ELD 01 Regulatable...

Страница 8: ... is the responsibility of a qualified electrician The machine can be either hard wired or connected via a socket in compliance with IEC 60309 1 Wall socket or mains isolator must be accessible after installation It is always recommended to make electrical connection via a plug and socket so that electrical safety checks e g during repair or service work can be carried out easily If it is necessary...

Страница 9: ...n incl Y piece 1 supplied On site threaded union in accordance with DIN 44991 flat sealing Inch 1 male thread Connection hose length mm 1500 Average water requirements for a standard 60 C Cottons programme calculated using cold hot and hard water supplies l h approx 124 In the absence of a hot water supply add sufficient water to reach the required amount If connecting to raw water subtract water ...

Страница 10: ...ately anchored to the floor Fastening material included with unit 2 angled brackets from transport strut 2 wood screws DIN 571 Ø length mm 8 x 80 2 wall plugs Ø length mm 12 x 60 The installation surface must be sufficiently stable and solid The fastening material provided is designed for securing the machine to a concrete floor only Fasteners for other floor types must be provided on site On conc...

Страница 11: ...of lid mm 400 Net weight kg 495 Max floor load in operation N 6076 Max static floor load N 5543 Max dynamic floor load N 533 Max drum rotation frequency Hz 18 3 Average heat dissipation to installation site depending on ambient temperature and programme selected W N A Installation should only be performed by qualified fitters in accordance with valid regulations relevant standards and health and s...

Отзывы: