background image

 

M.-Nr. 10 303 290 / 01 

 

 

 

Содержание PW 6137 D

Страница 1: ...06 15 M Nr 10 303 290 01 Installation plan Washer extractor PW 6207 D en GB ...

Страница 2: ...M Nr 10 303 290 01 2 ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...mm 240 Width mm 920 Depth mm 1019 BS Concrete platform Recommended height mm 240 Minimum height mm 100 Plinth width min mm 920 Min plinth depth mm 1050 DAV Steam connection valve The steam connection valve to regulate the steam supply must be provided on site The following valves can be ordered separately as electric steam valves or as pneumatic steam valves Electric steam valve ELD 01 Regulatable...

Страница 8: ... is the responsibility of a qualified electrician The machine can be either hard wired or connected via a socket in compliance with IEC 60309 1 Wall socket or mains isolator must be accessible after installation It is always recommended to make electrical connection via a plug and socket so that electrical safety checks e g during repair or service work can be carried out easily If it is necessary...

Страница 9: ...n incl Y piece 1 supplied On site threaded union in accordance with DIN 44991 flat sealing Inch 1 male thread Connection hose length mm 1500 Average water requirements for a standard 60 C Cottons programme calculated using cold hot and hard water supplies l h approx 124 In the absence of a hot water supply add sufficient water to reach the required amount If connecting to raw water subtract water ...

Страница 10: ...ately anchored to the floor Fastening material included with unit 2 angled brackets from transport strut 2 wood screws DIN 571 Ø length mm 8 x 80 2 wall plugs Ø length mm 12 x 60 The installation surface must be sufficiently stable and solid The fastening material provided is designed for securing the machine to a concrete floor only Fasteners for other floor types must be provided on site On conc...

Страница 11: ...of lid mm 400 Net weight kg 495 Max floor load in operation N 6076 Max static floor load N 5543 Max dynamic floor load N 533 Max drum rotation frequency Hz 18 3 Average heat dissipation to installation site depending on ambient temperature and programme selected W N A Installation should only be performed by qualified fitters in accordance with valid regulations relevant standards and health and s...