PW 6055/6065
en
– AU, NZ
= standard,
= optional, + = only on request, - not available
10 291 510 / 01
13
Technical data
PW 6055 AV
PW 6055 LP
PW 6065 AV
PW 6065 LP
Standard voltage (CDN only)
-
-
-
2 AC 208 V
Frequency
Hz
-
-
-
60
Total rated load
kW
-
-
-
4.0
Fuse rating
A
-
-
-
2 x 20
Supply lead min. cross-section
mm²
-
-
-
4 x AWG 10
Supply lead without plug for hard-wired connection
-
-
-
Length of supply lead
mm
-
-
-
2000
Standard voltage (USA only)
-
-
-
2 AC 208-240 V
Frequency
Hz
-
-
-
60
Total rated load
kW
-
-
-
4.0
Fuse rating
A
-
-
-
2 x 30
Supply lead min. cross-section
mm²
-
-
-
4 x AWG 10
Supply lead without plug for hard-wired connection
-
-
-
Length of supply lead
mm
-
-
-
2000
C o l d w a t e r ( K W )
Permissible water flow pressure
kPa
100 - 1000
100 - 1000
100 - 1000
100 - 1000
Required flow rate (cold water connection only)
l/min
11
11
11
11
Required flow rate (with additional hot water connection)
l/min
10
10
10
10
Average water consumption (60°C standard programme)
l/h
36
36
40
40
Connection to be provided on site, external thread according to AS 3688
Inch
¾“
¾“
¾“
¾“
Connection hose ½“ with ¾“ threaded union
Connection hose length
mm
1550
1550
1550
1550
H o t w a t e r ( W W )
Max. water intake temperature
°C
70
70
70
70
Permissible water flow pressure
kPa
100 - 1000
100 - 1000
100 - 1000
100 - 1000
Min. flow rate
l/min
11
11
11
11
Average water consumption (60°C standard programme)
l/h
13
13
13
13
Connection to be provided on site, external thread according to AS 3688
Inch
¾“
¾“
¾“
¾“
Connection hose ½“ with ¾“ threaded union
Connection hose length
mm
1550
1550
1550
1550
A l t e r n a t i v e w a t e r s u p p l y ( B W )
Kit with additional inlet valve
Permissible water flow pressure
kPa
100 - 1000
100 - 1000
100 - 1000
100 - 1000
Min. flow rate
l/min
11
11
11
11
Average water consumption (60°C standard programme)
l/h
14
14
17
17
Connection to be provided on site, external thread according to AS 3688
Inch
¾“
¾“
¾“
¾“
Connection hose ½“ with ¾“ threaded union
Connection hose length
mm
1550
1550
1550
1550
D r a i n v a l v e ( A V )
Connection (ext. diameter)
mm
75 (DN70)
-
75 (DN70)
-
Drainage temperature, max.
°C
90
90
Max. transient flow rate
l/min
62
-
62
-
D r a i n p u m p ( L P )
Hose connection (external diameter)
mm
-
22 (DN22)
-
22 (DN22)
Drainage temperature, max.
°C
-
90
-
90
On-site hose sleeve (int. diameter x length)
mm
-
22 x 30
-
22 x 30
Max. transient flow rate
l/min
-
26
-
26
Max. head height (from lower edge of machine)
mm
-
1000
-
1000
Drain hose DN 22 with connector (supplied as standard)
-
-
Connection hose length
mm
-
1500
-
1500
E q u i p o t e n t i a l b o n d i n g ( P A)
Machine connection (separate kit required)
Содержание PW 6055 AV/LP
Страница 3: ...PW 6055 6065 en AU NZ 10 291 510 01 3 Machine dimensions PW 6055 ...
Страница 4: ...en AU NZ PW 6055 6065 4 10 291 510 01 Installation PW 6055 ...
Страница 5: ...PW 6055 6065 en AU NZ 10 291 510 01 5 Washer dryer stack PW 6055 ...
Страница 6: ...en AU NZ PW 6055 6065 6 10 291 510 01 Machine dimensions PW 6065 ...
Страница 7: ...PW 6055 6065 en AU NZ 10 291 510 01 7 Installation PW 6065 ...
Страница 8: ...en AU NZ PW 6055 6065 8 10 291 510 01 Washer dryer stack PW 6065 ...
Страница 9: ...PW 6055 6065 en AU NZ 10 291 510 01 9 Installation ...
Страница 10: ...en AU NZ PW 6055 6065 10 10 291 510 01 Installation ...