Technical data
PW 6055 AV
PW 6055 LP
PW 6065 AV
PW 6065 LP
Drum volume
l
54
54
59
59
Load capacity
kg
5.5
5.5
6.5
6.5
Door opening diameter
mm
282
282
282
282
Max. spin speed
rpm
1400
1400
1400
1400
g factor
526
526
526
526
Residual moisture (standard load per DIN 60456)
%
49
49
49
49
E l e c t r i c a l c o n n e c t i o n ( E L )
Standard voltage
2N AC 400 V
2N AC 400 V
2N AC 400 V
2N AC 400 V
Frequency
Hz
50
50
50
50
Total rated load
kW
5.5
5.5
5.5
5.5
Fuse rating (B trip rating according to EN 60898)
A
2 x 16
2 x 16
2 x 16
2 x 16
Supply lead min. cross-section
mm²
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
Supply lead without plug for hard-wired connection
Length of supply lead
mm
1800
1800
1800
1800
Alternative voltage (convertible by Service)
1N AC 230 V
1N AC 230 V
1N AC 230 V
1N AC 230 V
Total rated load
kW
2.85
2.85
2.85
2.85
Fuse rating (B trip rating according to EN 60898)
A
1 x 16
1 x 16
1 x 16
1 x 16
Supply lead min. cross-section
mm²
3 x 1.5
3 x 1.5
3 x 1.5
3 x 1.5
Non-standard voltage OS 440 (Offshore)
-
-
3 AC 440 V
3 AC 440 V
Frequency
Hz
-
-
60
60
Total rated load
kW
-
-
5.05
5.05
Fuse rating (B trip rating according to EN 60898)
A
-
-
3 x 16
3 x 16
Supply lead min. cross-section
mm²
-
-
4 x 1.5
4 x 1.5
Supply lead without plug for hard-wired connection
-
-
Length of supply lead
mm
-
-
1800
1800
Non-standard voltage OS 400 (Offshore)
-
-
-
3 AC 400 V
Frequency
Hz
-
-
-
50
Total rated load
kW
-
-
-
4.2
Fuse rating (B trip rating according to EN 60898)
A
-
-
-
3 x 16
Supply lead min. cross-section
mm²
-
-
-
4 x 1.5
Supply lead without plug for hard-wired connection
-
-
-
Length of supply lead
mm
-
-
-
2000
Non-standard voltage OS 230 (Offshore)
-
-
-
3 AC 230 V
Frequency
Hz
-
-
-
60
Total rated load
kW
-
-
-
4.4
Fuse rating (B trip rating according to EN 60898)
A
-
-
-
3 x 16
Supply lead min. cross-section
mm²
-
-
-
4 x 1.5
Supply lead without plug for hard-wired connection
-
-
-
Length of supply lead
mm
-
-
-
2000
V a r i a t i o n s i n t h e f o l l o w i n g c o u n t r i e s :
Standard voltage 13A (GB only)
2N AC 400 V
2N AC 400 V
2N AC 400 V
Frequency
Hz
-
50
50
50
Total rated load
kW
-
5.5
5.5
5.5
Fuse rating (B trip rating according to EN 60898)
A
-
2 x 13
2 x 13
2 x 13
Supply lead min. cross-section
mm²
-
4 x 1.5
4 x 1.5
4 x 1.5
Supply lead without plug for hard-wired connection
-
Length of supply lead
mm
-
2000
2000
2000
Alternative voltage (convertible)
-
1N AC 230 V
1N AC 230 V
1N AC 230 V
Total rated load
kW
-
2.85
2.85
2.85
Fuse rating (B trip rating according to EN 60898)
A
-
1 x 13
1 x 13
1 x 13
Supply lead min. cross-section
mm²
-
3 x 1.5
3 x 1.5
3 x 1.5
Содержание PW 6055 AV/LP
Страница 3: ...PW 6055 6065 en AU NZ 10 291 510 01 3 Machine dimensions PW 6055 ...
Страница 4: ...en AU NZ PW 6055 6065 4 10 291 510 01 Installation PW 6055 ...
Страница 5: ...PW 6055 6065 en AU NZ 10 291 510 01 5 Washer dryer stack PW 6055 ...
Страница 6: ...en AU NZ PW 6055 6065 6 10 291 510 01 Machine dimensions PW 6065 ...
Страница 7: ...PW 6055 6065 en AU NZ 10 291 510 01 7 Installation PW 6065 ...
Страница 8: ...en AU NZ PW 6055 6065 8 10 291 510 01 Washer dryer stack PW 6065 ...
Страница 9: ...PW 6055 6065 en AU NZ 10 291 510 01 9 Installation ...
Страница 10: ...en AU NZ PW 6055 6065 10 10 291 510 01 Installation ...