background image

en - GB 

PW 5065 

12 

 

10 144 240 / 01 

Installation and planning notes  

Installation requirements 

Electrical connection should only be made to a power supply provided 
in accordance with all appropriate local and national legislation and 
regulations. 

In addition, all regulations issued by the appropriate utilities as well as 
standards relating to occupational safety, and all applicable valid 
regulations and technical standards must be observed! 

Transportation and site access 

The machine must not be moved without the transit bars in place. 
Keep the struts in a safe place. They must be re-fitted if the machine 
is to be moved again (e.g. when relocating machine). 

General operating conditions 

Ambient temperature in installation room: +2°C to +35°C. 

Depending on the nature of the installation site, sound emissions and 
vibration may occur. Miele recommends consulting a specialist if 
particular requirements apply at the installation site with respect to 
sound emissions. 

Electrical connection 

Depending on the model, the machine is delivered with a supply lead 
with/without a plug. 

The washer may only be connected to an electrical system that 
conforms to the national and local codes and regulations. The 
installation must be performed by a qualified electrician. 

The appliance data plate indicates the nominal power consumption 
and the appropriate fuse capacity. Compare the specifications on the 
data plate with those of the electrical power supply. 

The machine can be hard-wired or connected using a switched 
connection in accordance with IEC 60309-1. It is always 
recommended to make electrical connection via a plug and socket so 
that electrical safety checks, e.g. during repair or service work, can be 
carried out easily. 

If the machine is hard wired, a dual circuit breaker must be provided 
on-site. When switched off there must be an all-pole contact gap of 3 
mm in the isolator switch (including switch, fuses and relays according 
to IEC/EN 60947).  

The plug connectors or isolator switch should be easily accessible for 
servicing work. If the machine is disconnected from the electricity 
supply ensure adequate measures are taken to ensure that the 
machine cannot be reconnected to the electricity supply until all work 
has been carried out. 

New connections, modifications to the system or servicing of the 
ground conductor, including determining the correct fuse amperage, 
must be carried out by a qualified electrician, as they are familiar with 
the pertinent regulations and the specific requirements of the electric 
utility company. 

If converting the machine to an alternative voltage, observe the 
instructions in the wiring diagram. Conversion must be performed 
by an authorised agent or a Miele service technician. The heater 
rating must also be properly set. 

The machine must be permanently connected to the electricity supply 
so that the door can be opened. For this reason, it must not be 
connected to devices such as timers which would switch it off 
automatically. 

References to cable cross-sections in the technical data refer only to 
the required supply lead. Please consult relevant local and national 
regulations when calculating any other wire gauges. 

Cold water connection 

The machine should be connected to a mains water supply in 
accordance with current local and national regulations on water 
safety. 

Connection to the water supply should be carried out by a qualified 
plumber using a stopcock with a threaded union. If a stopcock is not 
available, a qualified plumber should connect the machine to the 
water supply. 

A suitable connection hose with a threaded union is provided with the 
machine. 

Longer hoses (2.5 or 4.0 m in length) are available from Spares as 
separate items. 

Hot water connection 

The same connection requirements as for cold water also apply to hot 
water (max. 70°C). 

A suitable connection hose with a threaded union is provided with the 
machine. 

The machine can be connected to a hot water supply of 70°C to max. 
85°C. This requires the use of a separate heat-resistant inlet hose. 

This additional hose must be obtained from Miele Spares. In addition, 
the appliance must be programmed accordingly by Miele Customer 
Service or an authorised agent. 

Connection to hot water only is not possible for functional reasons. 

In the event that hot water is not available on site, connection of the 
second hose must be made to a cold water supply. 

Alternatively, the hot water connection should be blocked using the 
enclosed blind stopper and the machine controls set to cold water 
intake.  

The required amount of hot water should be added to the cold water 
volume. 

Machine connection (depending on model) 

The washer-extractor is drained using a motorised drain valve. The 
machine can be connected directly to the on-site drainage system 
(without an odour trap) or via a floor drain (floor drain with odour trap). 

A vented drainage system is vital for unimpeded drainage. If on-site 
venting is insufficient, a vent kit (Mat. no. 05239540) is available from 
Miele Spares or authorised dealers. 

If several machines are connected to a single drain pipe, this should 
be sufficiently large to allow all machines to drain simultaneously. 

Drain pump (depending on model) 

The machine drains through a pump with a 1 m delivery head. For the 
water to drain freely, the hose must be free of kinks. The swivel elbow 
at the end of the hose can be turned in either direction, or removed as 
needed with a sharp twist and pull. 

Drain hose connection: 

1. Connected securely to a plastic drain pipe with a rubber sleeve. 
There is no need for a U-pipe. 

2. Connected to a sink using a plastic nipple. 

3. Connected securely to a floor drain. 

 

 

Содержание PW 5065 AV

Страница 1: ...AV LP To avoid the risk of accidents or damage to the machine it is essential to read operating and installation instructions before installation and commissioning This prevents both personal injury and damage to the machine en GB 10 144 240 01 ...

Страница 2: ...n pump B Machine anchors PA Equipotential bonding BW Grey water connection SLA Peak load connection DOS Dispenser connection UG Box plinth EL Electrical connection UO Open plinth F Machine feet adjustable WTV Washer dryer stacking kit KG Payment system WW Hot water connection KGA Payment system connection XKM Communication module All rights reserved 12 14 153 ...

Страница 3: ...PW 5065 en GB 10 144 240 01 3 Machine dimensions ...

Страница 4: ...en GB PW 5065 4 10 144 240 01 Installation ...

Страница 5: ...PW 5065 en GB 10 144 240 01 5 Washer dryer stack ...

Страница 6: ...en GB PW 5065 6 10 144 240 01 Installation ...

Страница 7: ...PW 5065 en GB 10 144 240 01 7 Installation ...

Страница 8: ... EN 60898 A 3 x 16 Supply lead min cross section mm 4 x 1 5 Supply lead without plug for hard wired connection Length of supply lead mm 1800 Non standard voltage OS 230 Offshore 1N AC 230 V Frequency Hz 60 Total rated load kW 3 2 Fuse rating B trip rating according to EN 60898 A 1 x 16 Supply lead min cross section mm 3 x 1 5 Supply lead without plug for hard wired connection Length of supply lead...

Страница 9: ... to EN 60898 A 3 x 16 3 x 16 Supply lead min cross section mm 3 x 1 5 3 x 1 5 Supply lead with plug Length of supply lead mm 2000 2000 Standard voltage AUS only 1N AC 230 V Frequency Hz 50 Total rated load kW 2 85 Fuse rating A 1 x 16 Supply lead min cross section mm 3 x 1 5 Supply lead with plug Length of supply lead mm 2000 Standard voltage CDN only 2 AC 208 V Frequency Hz 60 Total rated load kW...

Страница 10: ...ose DN 22 with connector supplied as standard Connection hose length mm 1500 Equipotential bonding PA Machine connection separate kit required Peak load energy management SLA Machine connection separate kit required Control signal voltage AC 230 V AC 230 V Payment system connection KGA Connection of payment systems Liquid dispensing DOS Connection for liquid detergents conversion kit required No o...

Страница 11: ...ate to installation site W 250 250 Options Accessories Features Box plinth UG Box plinth H 300 mm UG 5005 Galvanised plinth stainless steel sides Box plinth H 470 mm UG 5005 47 Galvanised plinth octoblue stove finished side panels Box plinth H 750 mm UG 5005 75 Galvanised plinth octoblue stove finished side panels Open plinth UO Open plinth H 300 mm UO 5005 Galvanised plinth octoblue stove finish ...

Страница 12: ...technician The heater rating must also be properly set The machine must be permanently connected to the electricity supply so that the door can be opened For this reason it must not be connected to devices such as timers which would switch it off automatically References to cable cross sections in the technical data refer only to the required supply lead Please consult relevant local and national ...

Страница 13: ...an be fitted with a single machine payment system optional accessory The necessary programming should only be performed by a qualified agent or by Miele Service Alternatively a wireless multi machine system for a maximum of 8 units can be connected to a Geldkarte payment system and further controls used to monitor machines Serial interface The serial interface is provided by an additional XKM RS32...