Installation plan: PT 8807
EL
Date:
2
01
5-Sep-15
Page:
8
Technical datasheet
Tumble dryer:
Heating:
PT 8807
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete
base
Quality and density of concrete must comply with load.
Concrete plinth must be firmly secured to floor!
Recommended height
mm
100
4“
Minimum height
mm
50
2“
Minimum width
mm
1.200
47“
Minimum depth
mm
1.400
55“
Machine connections:
Electrical
connection
V
oltage
V
3 AC 208
Frequency
Hz
60
Rated load
kW
27
.4
Fuse rating
A
3 ×
9
0
Connection cable, min. cross-section
mm²
AWG 16
Cable screw connector
M 50
Connection cable to be ordered separately
.
Electrical connection must comply with national
regulations
If machines are hard-wired, a multi-pole main switch must
be provided on site.
A wall socket or main isolator must be accessible after
installation.
Equipotential
bonding
Connection with male thread
mm
10 × 35
with washers and nut
M
10
Accessories not included
.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Peak load
energy
management
Control contact voltage
V
AC 230
Connection cable, min. cross-section
mm²
5 × 1,5
Connection cable to be ordered separately
.
Connection via a flexible supply lead with a separate
isolator is recommended. The isolator should be visible
and easily accessible after machine installation.
Vented
m³/h
1.100
38,85 cu ft/h
Max. Nominal air flow in vented mode
Max. Permissible pressure loss
Connection on machine side (ext. diameter)
mm
150
6“
Connection pipe provided on site (int. diameter)
mm
150
6“
Max. temperature
°C
80
176 °F
As relative humidity inside the vent ducting can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Pa
300
0.04 PSI