Adding and dispensing process chemicals
51
Wipe up any spilled process chemical thoroughly. Then start the
Rinse
program to prevent over-foaming from occurring during the
next program.
Refill indicator
When the fill level is low in the (DOS 2) supply container for
neutralizing agent or rinse aid you are reminded to refill it.
Refill rinse aid
This message also appears when dispensing neutralizing agent.
When refilling the reservoir make sure you are using the correct
process chemical.
Confirm the message shown with
OK
and
refill the process chemical as described above.
Dispensing
For information about setting the dispensing concentration, see
"Additional settings / Additional functions / Dispensing systems".
If spots appear on items after reprocessing:
Reduce the amount if using
neutralizing agent
.
Increase the amount if using
rinse aid
.
If clouding or smearing appears on items:
Increase the amount if using
neutralizing agent
.
Reduce the amount if using
rinse aid
.