Electrical connection
63
16.4 Connecting the drain hose
Caution
The drain hose may not be shortened or damaged.
Do not bend the drain hose when laying it.
The drain hose is located in the machine.
INFO
The machine is equipped with a drain pump. The on-site water drain must have a trap. The
maximum height of the on-site water drain is 600 mm.
Connect the drain pipe (A) to the machine.
Connect the drain pipe to the on-site water drain.
17 Electrical
connection
Danger
Danger to life: Live components!
The machine and the relevant additional devices must be connected by an electrical
company authorised by the relevant electricity supplier as per the locally applicable
standards and regulations.
When performing installation and maintenance work, disconnect the machine from the pow-
er network. Check that there is no voltage.
The electrical safety of this machine is guaranteed only if it is connected to a correctly installed protective
circuit and a residual current circuit breaker. It is very important that this basic safety requirement is
tested and in case of doubt the house installation is checked by a qualified electrician.
The circuit diagram must be observed.
The equipment may only be operated at the voltages and frequencies specified on the data plate.
A fixed connection must as a priority be installed for machines that are delivered without a power cord.
When the machine must be permanently connected (without a plug), a mains disconnector with all-pole
separation from the network must be installed. The mains disconnector switch must have a contact
opening width of at least 3 mm, and must also be lockable in the neutral position.
The electrical connection must be secured as a separately fused circuit with slow fuses or circuit
breakers. The protection depends on the total power consumption of the machine. The total connected
load is specified on the data plate of the machine
In the electric supply line, install a universal current sensitive residual-current circuit breaker class B with
a tripping current of 30 mA (DIN VDE 0664) as a frequency inverter is located in the machine.
Machines delivered from the factory equipped with mains cable and safety plug (single phase), or CEE
plug are (triple phase), may only be connected to the mains network indicated on the data plate.
17.1 Connecting the mains cable
Requirements for the mains cable
Cable type: Type H07 RN-F or equivalent
The wires must be fitted with wire end ferrules.
Cross section and number of cores: suitable for on-site power and protection
for more information see the sticker in the front panel
Machines delivered from the factory equipped with mains connection cable and safety plug (single phase), or
CEE plug are (triple phase), may only be connected to the mains network indicated on the nameplate. In
such machines, the bridges of the boiler heating element have already been connected. They may not be
changed to avoid overloading the plug.