Installation site
The appliance should be installed in a
dry, well ventilated room.
Do not install the appliance:
- outdoors,
- in an environment with dripping
water,
- in rooms which are at risk of frost.
The installation location should not be
exposed to direct sunlight, nor near a
heat source, such as an oven,
radiator, etc.
The ambient temperature should not
drop below 55 °F (13 °C) or rise above
110 °F (43 °C), otherwise malfunctions
may occur.
If installation next to a heat source is
unavoidable, observe the following
minimum distances from the heat
source:
– 1
1
/
4
" (3 cm) from an electric cooktop
or electric oven.
– 12" (30 cm) from a gas or oil
cooktop, range or oven.
The following should also be taken into
consideration:
– The electrical outlet must be easily
accessible in case of an
emergency,not concealed behind
the appliance.
– The plug and cord must not touch
the rear of the appliance as they
could be damaged by vibrations
from the appliance.
– Do not plug in other devices behind
this appliance.
– If the room is too cold, it will cause
the cooling system in the appliance
to remain off for too long.This can
cause the temperature in the
appliance to rise, resulting in
damage.
Base
A fully loaded appliance is very heavy.
The load-bearing capacity of your floor
must meet the following requirements:
KWT 16x3 SF
. . . . . . . 741 lbs (336 kg)
To ensure that the appliance is installed
securely and functions properly, the
base must be flat, level and made of a
hard, rigid material.
If in doubt, contact Miele.
Furniture/fixtures
The new appliance will be mounted
securely to adjacent and overhead
furniture/fixtures.
For this reason it is essential that all
attachable furniture/fixtures are
connected securely to the base or the
wall by suitable means.
Ventilation
The air intake and outlet must not be
blocked or covered in any way. They
also need to be dusted/cleaned on a
regular basis.
Installation
37
Содержание KWT 1603 SF
Страница 7: ...Door dimensions open min 90 A KWT 16X3 SF 26 5 8 677 mm Dimensions 40 ...
Страница 8: ...Niche dimensions A B KWT 16x3 SF 24 622 2 mm 24 610 mm Dimensions 41 ...
Страница 27: ...60 ...
Страница 28: ...61 ...
Страница 29: ...62 ...
Страница 30: ...63 ...
Страница 31: ...M Nr 09 920 900 00 en US CA KWT 1603 SF KWT 1613 SF ...