background image

– The beam must cover the appliance

by at least 2" (50.8 mm).

^

Mark the installation height (lower
edge of the beam) on the rear wall of
the niche.

^

Select screws according to the
thickness of the wooden beam.
Example: 3 ½" (89 mm) screw for 2x4
beam.

^

Determine the number of screws
based on the cavity width, to ensure
that the beam will be attached
securely.

^

Locate wall studs near the rear wall
of the cavity and mark drill holes in
the beam.

^

Pre-drill the wooden beam.

^

Attach the wooden beam to the rear
wall of the niche.

Sliding the appliance into the
installation niche

If a side-by-side installation is
desired, connect the two appliances
together. See the Installation Manual
included with the "Merging Kit".

^

Unscrew the plinth.

^

To protect the corners of the
installation space, attach edge
protectors where needed (not
included).

Installation

51

Содержание KWT 1603 SF

Страница 1: ...ons KWT 1603 SF en CA Installation repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions ...

Страница 2: ...terials that can be recycled Please contract your local recycling authority about the possibility of recycling these materials Instead please contact your municipality s waste collection center to return and recycle electric and electronic appliances Please take care not to damage the pipework while the appliance is being stored for transport to a waste disposal facility By protecting the pipework...

Страница 3: ...ly installed and secured as per the installation instructions Empty weight of your machine KWT 16X3 SF 375 lbs 170 kg Climate Range The appliance is designed for use within certain climate ranges ambient temperatures and should not be used outside this range The climate range of this appliance is stated on the data plate inside the appliance Climate range Ambient room temperature SN N ST T 50 F 10...

Страница 4: ...t not touch the rear of the appliance as they could be damaged by vibrations from the appliance Do not plug in other devices behind this appliance If the room is too cold it will cause the cooling system in the appliance to remain off for too long This can cause the temperature in the appliance to rise resulting in damage Base A fully loaded appliance is very heavy The load bearing capacity of you...

Страница 5: ...ged Single column The appliance can be installed at any preferred location in the kitchen However be sure the door will open and close properly in the chosen location Side by side This appliance can be installed side by side with another fridge freezer using a Merging Kit The Merging Kit is available from Miele Contact Miele or your dealer for specific information about which combinations will wor...

Страница 6: ...ually installed within its own niche using the mounting accessories included the Merging Kit is not necessary Side panels If one side of the appliance is visible a side panel must be used The side panel must be firmly secured to the wall the floor and the overhead furniture fixtures before the appliance is placed in the cavity The dimensions of the side panel are taken from the opposite wall of th...

Страница 7: ...Door dimensions open min 90 A KWT 16X3 SF 26 5 8 677 mm Dimensions 40 ...

Страница 8: ...Niche dimensions A B KWT 16x3 SF 24 622 2 mm 24 610 mm Dimensions 41 ...

Страница 9: ...Power supply 1 Power supply A KWT 16X3 SF 12 305 mm Power bars or extension cords are not safe risk of fire Do not use them to connect the appliance to the power supply Dimensions 42 ...

Страница 10: ...al codes In Canada the Canadian Electric code C22 1 latest edition Provincial and Municipal codes and or local codes Tools needed for installation Cordless screwdriver Torx screwdriver Hammer drill Wood drills in different sizes Hammer Rachet 5 16 8 mm Adhesive tape Multi grip pliers Level Tape measure Square When fastening the cabinet to the wall behind it see Installing the appliance use suitabl...

Страница 11: ...allation space complies with the installation requirements Check the base see Installation Check the dimensions of the cavity Check that the cavity is square Check the location of the power outlet Check that all furniture parts in the vicinity of the appliance are securely connected to the wall Check that the adjacent furniture fixtures do not collide with the open door Before installation Caution...

Страница 12: ...e carefully lift it from the pallet Once the appliance is on the ground it can be rolled around RemoteVision module installation optional accessory Always disconnect the appliance from the power supply when performing installation maintenance or service work Install the RemoteVision module before placing the appliance in its installation niche Once connected the RemoteVision module will increase t...

Страница 13: ... If the indicator light does not come on installation of the module was unsuccessful In that case repeat the process If that does not correct the problem contact Miele Pull the antenna d straight out Guide the cover b over the antenna d and screw on the cover Angle the antenna d so that it faces to the right or left If necessary disconnect the power supply and continue installing the appliance If ...

Страница 14: ... authorized agent from alarm company to connect your home s security system to the wine cellar Always disconnect the appliance from the power supply before performing installation maintenance or service work Remove the toe kick panel from the appliance Choose the desired switching contact and connect according to alarm system requirements Output of the Home Security System on the electronic board ...

Страница 15: ...ing Several plastic bags are included which are numbered alphabetically The bag needed for each step will be marked with its respective letter Anti tip brackets The anti tip brackets a keep the appliance safely secured in the installation niche b and prevent it from tipping Risk of tipping The installation niche must be securely attached to the wall behind it This is the only way the appliance whi...

Страница 16: ...plications materials If the anti tip brackets cannot be attached securely with the screws supplied an alternative anti tip device can be used Assure that there are no electrical wires or plumbing in the area which the screws could penetrate risk of injury and damage Now attach the installation niche to the wall The built in cabinet must be secured to the wall behind it with several screws In a cab...

Страница 17: ...ached securely an alternative anti tip device can be used Ensure that there is no give between the appliance and the anti tip device If possible always screw the wooden beam to existing studs Cut a wooden beam cross section min 3 x 4 75 mm x 100 mm to the required length The length is equal to the width of the installation niche If the installation cavity is deeper than the appliance select a beam...

Страница 18: ...beam will be attached securely Locate wall studs near the rear wall of the cavity and mark drill holes in the beam Pre drill the wooden beam Attach the wooden beam to the rear wall of the niche Sliding the appliance into the installation niche If a side by side installation is desired connect the two appliances together See the Installation Manual included with the Merging Kit Unscrew the plinth T...

Страница 19: ...de the appliance into the space If resistance is felt when attempting to slide the appliance into the installation niche for example because the floor is uneven Turn the rear adjustable wheels slightly outward see Aligning the appliance then push the appliance in Be careful not to damage the power cord attached to the floor Remove the edge protectors Aligning the appliance Align the appliance with...

Страница 20: ...m on the base max niche height of 85 3 16 2164 mm Align the appliance again using a level If using a wooden beam as an alternative anti tip device rotate the appliance all the way toward the wooden beam Attaching the appliance to the installation niche Open the appliance door Fasten the appliance on the left and right hand sides with the 3 supplied wood screws If there is a fairly large gap above ...

Страница 21: ...not cover ventilation slits in the plinth Risk of damage to the appliance If required cut the toe kick cover to the required length and height Attach the plinth to the appliance Put the included cover plates in place Remove the foil from the adhesive strips Attach the toe kick cover to the plinth Installation 54 ...

Страница 22: ...flowing into the machine optimizing the energy performance of the unit If necessary shorten the three parts of the air separator Insert the foam pieces back into the sides Position the air separator in the center of the appliance door From below screw the air separator firmly onto the door with the 2 screws Installation 55 ...

Страница 23: ...estions regarding the electrical connection of this appliance to the power supply please consult a licensed electrician or call the Miele Technical Service U1 800 999 1360 V1 800 565 6435 The appliance is supplied with a UL listed 3 wire power cord and NEMA 5 15 P plug ready for connection to a 120 V 60 Hz supply The fuse rating is 15 amps The appliance requires a 3 wire receptacle The receptacle ...

Страница 24: ...stallation section of this manual Be sure your wireless system meets the following requirements A wireless router that supports an IEEE 802 11b g protocol Windows XP or newer operating system Mac OS X 10 3 or higher Cable or DSL modem Microsoft Internet Explorer 6 or higher Safari 2 0 or higher Firefox 1 5 or higher Please note that each wireless router manufacturer supplies their own device drive...

Страница 25: ...ess button p to confirm See the table on the following page for a description of each setting in the display Use the Y or X buttons to select the RemoteVision options The module has been connected to the network when appears in the display If does not appear refer to the Network options section of the XKM 2000 Installation Instruction manual Press and hold the access button p for 2 seconds to conf...

Страница 26: ...ork established no IP address assigned Solid Connected to network Flashing In Ad Hoc Mode not connected Flashing In Ad Hoc Mode connected Selectable options Description of function Back 2 Reboot the module 3 Reset to factory settings 4 Enter Ad Hoc Mode Note If you cannot select any option other than Back the module has not been installed correctly RemoteVision optional accessory 59 ...

Страница 27: ...60 ...

Страница 28: ...61 ...

Страница 29: ...62 ...

Страница 30: ...63 ...

Страница 31: ...M Nr 09 920 900 00 en US CA KWT 1603 SF KWT 1613 SF ...

Отзывы: