Installation
*INSTALLATION*
20
Specifications for the plumbed
water connection
- The machine may only be connected
to the plumbed water connection by
qualified technicians.
- Connection to the household water
supply must comply with the applica-
ble regulations in the country in
which the machine is being installed.
All units and systems used to supply
water to the machine must also com-
ply with the applicable regulations in
the respective country.
- The water quality must comply with
the requirements for drinking water in
the country in which the machine is
being operated.
- The water pressure must be between
29 and 116 psi (2 and 8 bar).
- The appliance is only suitable for
connection to a cold water line.
- The appliance may only be con-
nected directly to a fresh water sup-
ply to ensure that water is circulated
in the cold water line.
- A shut-off valve must be provided
between the water line and the water
supply of the building to ensure that
the water supply can be cut off if
necessary.
- Make sure that the shut-off valve is
still accessible after the appliance
has been installed.