Water filter
118
Water filter
34
Performance Data Sheet
Model: Miele 07134220
Use Replacement Cartridge 07134220
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system as specifi ed in NSF/ANSI Standard 42 and Standard 53.
System tested and certifi ed by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of the claims
specifi ed on the Performance Data Sheet.
Capacity 739.68 Gallons (2800 Liters)
Contaminant Reduction Determined by NSF testing.
Substance Reduction
Average
Infl uent
NSF specifi ed
Challenge
Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF Test
Report
Chlorine Taste and Odor
2.1 mg/L
2.0 mg/L ± 10%
97.6%
0.05 mg/L
N/A
≥ 50%
J-00121313
Nominal Particulate Class I,
≥0.5 to < 1.0 μm
9,100,000 pts/
mL
At least 10,000
particles/mL
98.8%
111,817 pts/ml
N/A
≥85%
J-00099871
Cyst*
170,000 cysts/L
Minimum 50,000
cysts/L
99.99%
0.001 cyst/L
N/A
≥99.95%
J-00109715
* Based on the use of Cryptosporidium parvum oocysts
FOR RESIDENTIAL USE ONLY
Application Guidelines/Water Supply Parameters
Service Flow
0.75 gpm (2.83 lpm)
Water Supply
Potable Water
Water Pressure
30 -120 psi (207 – 827 kPa)
Water Temperature
33ºF - 100ºF (0.6ºC - 38ºC)
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal
injury or property damage.
• Check with your local public works department for plumbing codes. You must
follow their guidelines as you install the water fi ltration system.
• Your water fi ltration system will withstand up to 120 pounds per square inch
(psi) water pressure. If your water supply pressure is higher than 80 psi, install a
pressure reducing valve before installing the water fi ltration system.
To reduce the risk associated with the ingestion of contaminants:
•
DO NOT use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certifi ed for
cyst reduction may be used on disinfected water that may contain fi lterable
cysts.
It is essential that the manufacturer’s recommended
installation, maintenance and fi lter replacement
requirements be carried out for the product to perform as
advertised. See Installation Manual for Warranty information.
Note:
While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge: 07622430
For estimated costs of replacement elements please contact
your local dealer, go to www.miele-shop.com or call
Tel. 0180 31 31 340 (€
0,09/Min.).
NOTICE
To reduce the risk associated with water leakage or fl ooding:
• Read and follow Use Instructions before installation and use of this system.
• Change the disposable fi lter cartridge every six months or sooner if you observe
a noticeable reduction in water fl ow rate.
• Failure to replace the disposable fi lter cartridge at recommended intervals may
lead to reduced fi lter performance and failure of the fi lter, causing property
damage from water leakage or fl ooding.
• For questions or concerns, please contact Customer Service at
Tel. 0180 31 31 340 (€0,09/Min.).
3M is a trademark of 3M Company used under license.
NSF is a trademark of NSF International.
© 2017 3M Company. All rights reserved.
34-8721-1445-8
Manufactured by:
3M Purifi cation Inc.
3130 Lexington Avenue South,
Eagan, MN 55121
Содержание KF 2981 Vi
Страница 132: ...Declaration of conformity 132 Frequency band 2 412 GHz 2 462 GHz Maximum trans mitting power 100 mW ...
Страница 134: ......
Страница 136: ...M Nr 10 785 190 04 en US CA KF 2981 Vi ...