Adjust the front feet with a ratchet (at-
tachment: socket, 8 mm) or a TX 20
screwdriver
.
Tip:
Proceed carefully when adjusting
the feet, alternating between the left
and right feet.
Place a spirit level across the installa-
tion aids
on the appliance door to
check the refrigeration appliance’s
alignment.
Unscrew the adjustable feet
and
on both sides at least until the
marking on the plinth has reached the
specified distance of 32 mm on the
spacer
. The standard dimension of
32 mm relates to a niche height of
2134 mm.
It is important to adjust the feet to a
height of at least 32 mm so that the
ventilation of the refrigeration appli-
ance via the plinth functions correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be dam-
aged.
Unscrew the feet
only until
the
marking on the plinth is aligned to a
maximum of 62 mm (max. niche
height of 2164 mm).