Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
118
Electrical connection
Danger of injury! All electrical work
should be undertaken by a suitably
qualified and competent person in strict
accordance with current national and
local safety and building code
regulations. Installation, repairs and
other work by unqualified persons
could be dangerous. Miele cannot be
held liable for unauthorised work.
Ensure power is not supplied to the
appliance until after installation or repair
work has been carried out. The
appliance is supplied with a mains
connection cable for connection to
AC 50 Hz, 230 V.
The fuse rating must be at least 16 A.
Connection to a switched socket is
recommended as this provides easier
access in the case of a service call.
Connection should be made via a
suitable isolator which complies with
national and local safety regulations.
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
current of 30 mA.
Ensure that the plug and switch are
accessible at all times.
If the appliance is hardwired or if the
switch is not accessible after
installation, an additional means of
disconnection must be provided.
When switched off there must be an all-
pole contact gap of 3 mm in the isolator
switch (including switch, circuit
breakers and relays).
Voltage, rated load and fuse rating
are given on the data plate situated at
the front of the oven compartment.
Please ensure these match the
household electricity supply.
If the connection cable is damaged, it
must be replaced by a suitably qualified
and competent person in order to avoid
a hazard.