For future servicing work, please
document any alterations to the stan-
dard factory settings.
Enter any alterations in the relevant
Value set:_________ box.
.
1. Setting the cold water inlet from:
Nominal water intake to Nominal wa-
ter 1 l.
The amount of water taken into the
machine at each intake can be
increased by 1 litre to a maximum of
9.5 litres.
To do this:
^
Turn the programme selector to STOP
f
.
^
Switch the machine off.
^
Press and hold
4
and
6
at the
same time, and whilst doing so
switch the machine on with the
I-0
button.
The current programme status “P...”
appears in the display and the
p
/
6
indicator lights up.
^
Press
3
once. E01 for programming
level 1 will appear in the display.
^
Turn the programme selector to the
D
position. A 10 or an 11 will appear
in the display.
10 = Nominal water intake
11 = Nominal water 1 l
^
Press
4
to change from 10 to 11 or
vice versa.
^
Press
6
. SP appears.
^
Press
6
again. The change has
been recorded.
Value set:
2. Selecting a second interim rinse
Interim Rinse II can be programmed in
to improve interim rinsing in all
programmes (except
D
PRE-RINSE).
^
Turn the programme selector to STOP
f
.
^
Switch the machine off.
^
Press and hold
4
and
6
at the
same time, and whilst doing so
switch the machine on with the
I-0
button.
The current programme status “P...”
appears in the display and the
p
/
6
indicator lights up.
^
Press
3
once. E01 for programming
level 1 will appear in the display.
^
Turn the programme selector to
o
. A
30 or an 31 will appear in the display.
30 = without Interim rinse II.
31 = with Interim rinse II.
^
Press
4
to change from 30 to 31 or
vice versa.
^
Press
6
. SP appears.
^
Press
6
again. The change has
been recorded.
Value set:
Programming special functions
33