![Miele G 7855 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/miele/g-7855/g-7855_operating-instructions-manual_234823035.webp)
4. Venting and setting the dosage on
DOS modules G 60 and C 60
(optional extra)
^
Set the dosage selector on the DOS
module to position 10 (applies to
DOS Module C 60 only).
^
Turn the programme selector to STOP
f
.
^
Switch the machine off.
^
Press and hold
4
and
6
at the
same time, and whilst doing so
switch the machine on with the
I-0
button.
The current programme status “P...”
appears in the display and the
p
/
6
indicator lights up.
^
Press
3
twice, E02 for programming
level 2 will appear in the display.
Venting the dispensing system:
^
Turn the programme selector to the
D
position. do1 appears in the
display.
^
Press
4
for 90 seconds.
The dispensing system will be vented
automatically.
If only venting is required:
^
Switch the machine off with the
I-0
button.
Immediately after this: start the
PRE-RINSE
D
programme, so that after
venting any agents in the wash cabinet
are diluted before being drained away.
Setting the dosage:
Set the dosage according to the
manufacturer’s recommendations.
The machine needs 7 litres of water in
the main wash stage of the programme.
Example:
A manufacturer recommends 4 ml
cleaning agent per litre of water:
7 l x 4 ml/l = 28 ml.
2 ml
.
1 second dispensing time; i.e.
programming to 14 seconds.
^
Turn the programme selector to
,
, the
dispensing time in seconds appears
in the display, e.g 10.
^
Press
4
repeatedly or hold it in, until
the number 14 appears in the display
(dispensing time 14 seconds
.
28 ml
- see example - ).
The dispensing time/amount is set.
^
Having changed a value or all
values:
^
Press
6
. SP appears.
^
Press
6
again. The change has
been recorded.
Value set:
If the dispensing system also needs to
be vented:
^
Start the PRE-RINSE programme
D
,
so that after venting any agents in the
wash cabinet are diluted before
being drained away.
Programming special functions