Height:
117.5 cm
Width:
90 cm
Depth:
70 cm
Depth with door open:
126.5 cm
Voltage:
see data plate
Connected load:
see data plate
Fuse rating:
see data plate
Mains connection cable:
approx. 1.8 m
Water temperature:
Hot, cold and AD water
max. 70 °C
Static water pressure:
Hot, cold and AD water
max. 1000 kPa (10 bar) pressure
Minimum flow pressure:
Cold and hot water
150 kPa (1.5 bar) pressure
AD-water
60 kPa (0.6 bar) pressure
Recommended flow pressure:
Cold and hot water
0
250 kPa (2.5 bar) pressure
AD-water
0
150 kPa (1.5 bar) pressure
AD-water connection (non-pressurised)
Optional
Delivery head:
min. 0.6 m, max. 1 m
Drainage length:
max. 4 m
Inlet hose:
approx. 1.7 m
Drain hose:
approx. 1.5 m
Steam condenser:
approx. 2-4 l/min
Ambient temperature
from 5 °C to 40 °C
Altitude
Max. 1500 m
#
Noise level in dB (A):
Sound level LpA
< 70
Test marks:
VDE, interference suppression, DVGW,
!
mark:
MDD-Guidelines 93/42/EWG, Class IIa
#
If installed at altitudes above 1500 m the boiling point of the suds solution will be
lower. Disinfecting temperature parameters should be lowered and the holding
time increased (A
0
value).
Technical data
59
Содержание G 7836 CD
Страница 63: ...63 ...