Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
46
Risk of damage due to condens-
ation on external appliance panels.
In environments with high humidity,
condensation can build up on ex-
ternal appliance panels, which can
cause corrosion.
To prevent this, it is advisable to in-
stall the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation, make sure that the
appliance door closes properly, that
the specified ventilation gaps are ad-
hered to, and that the refrigeration
appliance has been installed in ac-
cordance with these installation in-
structions.
Climate range
This refrigeration appliance is designed
for use within specific ambient temper-
atures (climate range). Do not use in
ambient temperatures for which it is not
designed.
A lower room temperature leads to the
compressor switching off for longer
periods. This can cause the internal
temperature in the refrigeration appli-
ance to rise with the risk of food deteri-
orating and going off.
The climate range is stated on the data
plate in the interior cabinet of the refri-
geration appliance.
Climate range
Ambient room
temperature
SN, N
Up to +32 °C
ST
Up to +38 °C
T
Up to +43 °C
A freezer from the SN climate range
can operate without any difficulties in
rooms with a cooler ambient temper-
ature (down to -15 °C).