Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
The minimum safe distance be-
tween the top of the cooker/hob and
the bottom of the cooker hood
should be at least
– 45 cm above electric cookers /
hobs
– 65 cm above gas cookers / hobs
– 65 cm above a Miele open grill.
See “Warning and Safety instruc-
tions” for further notes on safe installa-
tion.
Fitting procedure
1. Non-return flap (if required)
2. Reducing collar (if required)
3. Fit the runners in the wall unit
4. Fit and align the furniture door
5. Position the appliance in the wall unit
6. Align the height of the appliance
7. Fit the lightshield
8. Align the depth of the appliance
9. Fit the side spacers, the spacer
strip, and the light cover
10. Set up for air extraction or recircula-
tion
11. Connect to the electricity supply
Prepare the exhaust stub/ vent socket
for air extraction or recirculation before
installation.
1. Non-return flap
Air extraction
Fit the non-return flap into the vent
socket so that the flaps can open up-
wards.
(This is not necessary if the ducting
system is already fitted with a non re-
turn flap, e.g. wall vent).
Recirculation mode
When used in recirculation mode it is
not necessary to fit a non-return flap.