Figure 080-11:
Circuit Test Path for
F51
(Testing State)
Cause:
Heater relay defective; contact open.
Remedy:
Replace the heater relay. See Section 050-4.10.
Cause:
Heater relay solenoid defective.
Remedy:
Replace the heater relay. See Section 050-4.10.
Cause:
Connection from heater relay to electronic is open-circuited.
Remedy:
1. Check plug connections. Ensure that all plug connections are clean and
secure.
2. Check the connection wires for continuity.
Cause:
Heater pressure switch open- or short-circuited.
Remedy:
1. Ensure that the heater pressure switch is in positions 21/22 and 11/12. If
not, perform the following checks:
a. Ensure that all plug connections are clean and secure.
b. Check the connection wires for continuity.
c. Remove the heater pressure switch (Section 050-4.16) and check for
any blockages.
2. If the heater pressure switch still shows an open circuit, replace it.
Cause:
Foreign objects in heater pressure switch.
Remedy:
Replace the heater pressure switch. See Section 050-4.16.
Содержание Classic G 4205
Страница 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Страница 32: ...Technical Information 32 G 5xxx 010 Casing ...
Страница 39: ...Technical Information 39 G 5xxx 020 Door ...
Страница 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Страница 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Страница 63: ...Technical Information 63 G 5xxx Figure 030 7 Interference Suppression Capacitor and Ground Wire ...
Страница 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Страница 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Страница 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Страница 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...