Technical Information
137
G 5xxx
Circulation pump M6 is now activated for 2 minutes in order to wet the
dishes in the dishwasher and to fill any spaces with water. Drain pump
M8 is then activated for one minute. This creates a measurement basis
for the actual test.
During the test, water inlet valve Y63 is activated until a defined number
of pulses corresponding to a water volume of approximately 0.37 gallons
(1.4 liters) is reached. Circulation pump M6 is then activated once more.
b.
The program continues to run without interruption. The maximum water
intake time is extended to 4 minutes. This time value is saved by the
electronic for future water intake. For future water intakes, if the time
needed for 0.26 gallons to flow into the machine differs by 15 percent, a
new test routine flow will be started.
c.
If heater pressure switch B1/13 is activated, the program is interrupted
immediately, the drain pump is operated, and fault
F19
is registered.
Cause:
Flow meter defective.
Remedy:
Replace the water diverter. See Section 050-4.12.
Fault
F19
will be displayed if the check to test the sluggish movement of the
flow meter (impeller counter) during the water intake is not successful.
3.18
Fault Code F24:
Heater Relay Contact
Symptom:
The program is interrupted and the drain pump is operated.
Background information:
Figure 080-9:
Circuit Test Path for
F24
18 seconds after starting the drain sequence, the electronic will perform an
operational test on the
heater relay
. The circulation pump is not operating
and no power is applied to the heater relay coil. If 120VAC is registered at
ST5 on the electronic board, then an
F24
is logged in memory (see Figure
080-9). When the circulation pump is not operating, the heater relay contacts
are checked. If supply voltage is then applied to the electronic’s inputs, the
fault is registered.
Содержание Classic G 4205
Страница 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Страница 32: ...Technical Information 32 G 5xxx 010 Casing ...
Страница 39: ...Technical Information 39 G 5xxx 020 Door ...
Страница 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Страница 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Страница 63: ...Technical Information 63 G 5xxx Figure 030 7 Interference Suppression Capacitor and Ground Wire ...
Страница 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Страница 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Страница 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Страница 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...