3
A
Mark the correct selection here and have this sheet with you as you program
your console. It will make programming your console much easier. The most
commonly used selections are indicated by
Prime:
__________
Step 1
This is your application type.
(single conveyor)
(dual or split chain conveyor)
Distance:
__________
Step 2
This is a calibration number that must be checked.
The radar constant will vary with the type of radar.
Mid-Tech Compact Radar start at 780
DickeyJohn Radar start at 1000
Implement Width:
__________
Step 3
This is your swath in INCHES.
50 ft swath = 600 in
60 ft swath = 720 in
80 ft swath = 960 in
Total Applied:
__________
Step 4
This is your spreader constant from the chart
Have to know chain type & width plus encoder type
It must match the gate height.
Application Rate:
__________
Step 5
This is your product in lbs/cu ft.
If the product density is not correct,
the application rate will not be correct.
PD should be measured & entered with each load.
% Rate:
__________
Step 6
Change rate by 10% increments.
This is a personal choice.
Product Volume:
__________
Step 7
Enter as a constant In pounds
This is the total weight of product
in your hopper
12 ft body
—14000 lb max capacity
10 ft body
—12000 lb max capacity
C Stnrd
C SPL it
B
E
D
C
F
G
©2011 Newton Crouch Inc. This information is the property of Newton Crouch Inc. and is loaned confidentially to our customer for his sole use. It must not be used in any way
detrimental to our interest or shared with outside parties. Technical Tips/ ARC6000 Programming—Dry Rev 2.2.2011