Chapter 10: Troubleshooting
MESSAGE
Option
EXPLANATION
DATA CARD ERROR DATA
CARD NOT FORMATED. NO
DATA WILL BE WRITTEN
TO CARD UNTILCARD IS
FORMATTED.
If the data card is not
formatted. Attention
light flashes at 0.5
second intervals
Format the data card by selecting SETUP/FORMAT from the Main
Menu.
CHARGER ERROR
IS CHARGER TURNED ON?
ARE CABLES CONNECTED?
This occurs if the
bridge cannot talk
to the charger.
Make sure the charger is turned and the cables are connected. Also
make sure the Multitasker module is receiving power and is properly
connected between the Control Module and the charger.
WIRELESS ERROR
IS CHARGER TURNED ON?
ARE YOU WITHIN RANGE?
If wireless module
is connected and
message fails 4 times
this error appears.
This happens from Main Menu into charge feature or when results are
uploaded.
UNSTABLE BATTERY
DETECTED
A battery that is weak,
or that has just been
charged, may retain
enough electrical
activity to be detected
by the GR8 and will
adversely affect the
test results.
A fully charged battery should stabilize quickly, after which the GR8
will automatically retest. Weak batteries should be charged and
retested. If the battery is fully charged, check the clamp connections.