background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

DCA-8000

Page 

4

Quick Start Guide

167-000900EN-A

March 2019

www.midtronics.com

Corporate Headquarters

 

Willowbrook, IL USA

 

Phone:          1.630.323.2800
Canadian Inquiries

 

Toll Free:            +1 1 866 592 8052

 

 

Midtronics b.v.

European Headquarters

Houten, The Netherlands 

 

Serving Europe, Africa, the Middle

East, and The Netherlands

 

Phone:               +31 306 868 150

 

Midtronics China

 

China Operations

 

Shenzhen, China

 

Phone:   +86 755 2374 1010

 

 

 

Midtronics India

Navi Mumbai, India

Phone:     +91 22 2756 4103/1513

 

 

Contact Corporate Headquarters

Phone:                 +1.630.323.2800

Asia/Pacífic (excluding China)

Manual Entry

: Use the on-screen keypad to manually type 

the 17-digit VIN and tap 

Next

.

The displayed digit counter will count up the alphanumeric 

characters as they are entered on the keypad.

4.  The Edit Battery Information screen displays vehicle and bat-

tery information based on the VIN.
If the displayed information is correct, tap 

Next

 to begin the 

Battery Test or 

Reset

 to reset the parameters to the factory 

defaults.

5.  Tap the box across from each displayed parameter and se-

lect the correct information from the displayed list.

 

NOTE:

 

See Appendix B in the Instruction 

Manual for complete parameter descriptions.

 

NOTE

: Tap 

Find Battery

 to search for the bat-

tery location based on the vehicle year, make, 

and model based on the VIN or vehicle year, 

make, and model selected.

The charger performs a series of tests to determine the 

overall condition of the battery before applying a charge. 

Those steps include measuring the ambient battery 

temperature, Cranking Health, Reserve Capacity, Charge 

Acceptance, and applying a Load Test to the battery.

The test results are then displayed on the charger screen.

 

NOTE

: If the CVG was used to acquire the ve-

hicle information, the Edit Battery Information 

screen is displayed (See Step 3).  Tap 

Next

 to 

display the test results.

System Test

1.  Start the engine and let it idle.
2.  Turn off all electrical accessories such as headlights and the 

interior ventilation blower fan and tap 

Next

.

3.  The analyzer tests the alternator output at idle.
4.  When prompted, rev and hold the engine to between 2000 

to 3000 RPM and tap 

Next

.  The analyzer tests the alternator 

output again.

5.  When prompted idle the engine.
6.  Turn on the high beam headlights and interior ventilation 

blower motor and tap 

Next

.

7.  The analyzer tests the alternator output at idle.
8.  When prompted, rev and hold the engine to between 2000 

to 3000 RPM and tap 

Next

.

9.  The analyzer tests the alternator output again.
10.  When prompted turn off all loads and Idle the engine.
11.  Tap 

Next

 to display the test results.

System Test Results-Summary

Test Results - Summary

A Test Results - Summary screen is displayed following a System 

Test.  Tap 

>

 to view detailed test results for each part of the test.

 

NOTE:

 Refer to Appendix C: Test Result Decision 

Tables in the Instruction Manual for a complete ex-

plaination of possible test results.

To send the test results to a configured printer or via email tap 

Send Results

 and select an option.  To return to the Home 

Screen, tap 

Done

 or   to return to the Main Menu.