background image

13 

 
 

CHARGEXPRESS PRO OPERATING STEPS 

 

IMPORTANT NOTES: 

 

Clean the battery terminals.  If stud adapters are required, fasten them with the proper tool. Do not 
use the battery clamps to tighten adapters. 

 

Use stud adapters on Side-Post and/or Truck batteries that are not in the vehicle. 

 

Never remove the clamps from a battery to abort an active charging session.  Always push the 

 

Multi function ON/OFF button shortly before removing the clamps. 

 

Do not leave clamps lying in battery acid. 

 

Clean up any acid spills immediately (e.g., with baking soda and water). 

 

Clamps must be cleaned after every use. 

 

1. CONNECT CHARGEXPRESS PRO TO BATTERY 

Connect the CHARGEXPRESS PRO charging clamps to the battery in accordance with all precautions 
and safety instructions. 
 
IF YOU ACCIDENTALLY REVERSE THE CLAMP CONNECTIONS, THE CHARGEXPRESS PRO WILL 
INDICATE THIS WITH A RED LED AND BLINK RATE (01).  SWITCH CHARGER OFF BEFORE 
CHANGING CLAMPS. 
 

2. CONNECT TO POWER AC 

Plug the CHARGEXPRESS PRO into a dedicated, grounded 16 Amp AC outlet.  
Do not use an AC line cord adapter or extension cord.   
Switch on the charger. 
 

3. SELECT CHARGEXPRESS PRO MODES 

Use the Multi Function ON/OFF button to activate charger and selecting the battery technology used for 
charging the battery:  
Lead acid, AGM/SPIRAL, GEL, Power supply or Memory Saver 
 
After selecting one of the modes the charger will start charging automatically. 
This is indicated by the Orange LED. 
 

CHARGEXPRESS PRO FUNCTIONS 

 
To charge the different battery technologies the CHARGEXPRESS PRO has got a button to select one of 
the following: 
 

Battery technology 

U Boost 

U Float 

Flooded Lead acid; Calcium, Antimony 

16,50 / 14,20 

Pulse 13,5 – 14,8 

AGM / SPIRAL 

16,50 / 14,40 

Pulse 13,5 – 14,8 

GEL 

16,50 / 14,30 

Pulse 13,5 – 14,8 

Power Supply / Memory Saver 

N/a 

13,10 

 
 
 

Содержание ChargeXpress PRO 15

Страница 1: ...ChargeXpress PRO 15 PRO 25 PRO 25 2 INSTRUCTION MANUAL ...

Страница 2: ...2 ...

Страница 3: ...ON 10 FRONT PANEL 10 Multi function ON OFF buttons 11 Status LED s 11 Function LED 11 CHARGE SEQUENCE 12 POWER SUPPLY MODE 12 CHARGEXPRESS PRO OPERATING STEPS 13 IMPORTANT NOTES 13 1 CONNECT CHARGEXPRESS PRO TO BATTERY 13 2 CONNECT TO POWER AC 13 3 SELECT CHARGEXPRESS PRO MODES 13 CHARGEXPRESS PRO FUNCTIONS 13 TROUBLE SHOOTING 14 OPERATION 14 ERROR CODES 14 WARRANTY 15 TABLE OF CONTENT ...

Страница 4: ...POISON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS NO FLAMES SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS Always use the following precautions when working with batteries PRECAUTIONS ...

Страница 5: ... persons 6 To reduce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting CHARGEXPRESS PRO 7 Position AC and DC leads to avoid tripping over them and to prevent damage by hood doors or moving engine parts protect from heat oil and sharp edges 8 Do not operate CHARGEXPRESS PRO if it has received a sharp blow been dropped or otherwise damaged in any way take it t...

Страница 6: ... These batteries may burst and cause personal injury and property damage 9 NEVER charge a frozen battery thaw it out first Charging will then be safer and more efficient PREPARING THE BATTERY 1 If necessary to remove battery from vehicle to charge always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc 2 Use stud adapters on sid...

Страница 7: ... tripping over them and to prevent damage by hood doors or moving engine parts 3 Stay clear of fan blades belts pulleys and any other parts that can cause physical injury 4 Turn OFF all vehicle loads including door lights and correct any defects in car s electrical system that may have caused low battery 5 Check polarity of battery posts The POSITIVE post usually has larger diameter than NEGATIVE ...

Страница 8: ...oads are OFF to prevent a possible arc FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE A SPARK NEAR BATTERY MAY CAUSE AN EXPLOSION TO REDUCE RISK 1 Check polarity of battery posts POSITIVE post usually has larger diameter than NEGATIVE post 2 Connect POSITIVE RED CHARGEXPRESS PRO clamp to POSITIVE post of battery 3 Connect NEGATIVE BLACK CHARGEXPRESS PRO clamp to NEGATIVE post of battery ...

Страница 9: ... position 1 cable 2 goes into position 2 PRO 25 2 only Make sure the cables are connected nice and tidy under the strain relieve shown in position 3 using the bracket with the wing nut Plug in the main lead at position 4 1 Charge cable nr 1 2 Charge cable nr 2 PRO 25 2 only 3 Strain relieve 4 AC power cable FITTING INSTALLATIONS The charger can be mounted vertically or horizontally while maintaini...

Страница 10: ...e charging If there are any signs of a leaking or cracked case discard the battery Do not attempt to charge a battery that is in this condition FRONT PANEL 1 Function selection LED s 2 Multi Function ON OFF buttons 3 Status LED s OPERATION 1 2 3 1 2 3 1 2 3 ...

Страница 11: ...er OFF Button pressed short Stop charge cycle Button pressed long Switch on charger Button pressed long Switch off charger Status LED s Located at the bottom of the charger are two multi coloured LEDS Each charger channel has one LED assigned When the charger is switched on a self test is performed If something is not according to specification the multi coloured LED will turn RED Possible colours...

Страница 12: ...at any time during a charge cycle to stop the charger Position 1 Lead Acid charge curve 2 AGM ESPIRAL charge curve 3 GEL charge curve POWER SUPPLY MODE Integrated in the charger is also a Power Supply function This mode ensured that the battery is kept fully charged during programming of ECU s or regular vehicle maintenance When the charger is not yet switched on press and hold down one of the Mul...

Страница 13: ...CLAMP CONNECTIONS THE CHARGEXPRESS PRO WILL INDICATE THIS WITH A RED LED AND BLINK RATE 01 SWITCH CHARGER OFF BEFORE CHANGING CLAMPS 2 CONNECT TO POWER AC Plug the CHARGEXPRESS PRO into a dedicated grounded 16 Amp AC outlet Do not use an AC line cord adapter or extension cord Switch on the charger 3 SELECT CHARGEXPRESS PRO MODES Use the Multi Function ON OFF button to activate charger and selectin...

Страница 14: ...ect correctly to 12 V 04 Battery voltage too low 5 5 V Battery deeply discharged consider replacement battery might be damaged 05 Charge voltage problem no increase Consider battery replacement 06 Charge current problem no increase Battery replacement recommended 07 Too low charge current Battery replacement recommended 08 Internal current failure 09 Internal voltage failure Switch off unit press ...

Страница 15: ...imited warranty applies only to Midtronics battery charger and does not cover any other equipment wear and tear parts such as the cable static damage water damage over voltage dropping the unit or damage resulting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages for breach of this warranty The warranty is void if owner attempts to d...

Страница 16: ...16 168 953A EN 12 06 Midtronics Inc ...