54
1.
Under normal operating conditions, the green LED is on and the digital
display shows the input voltage (volts) and the outpower (kilowatts)
2.
Under error or alarm conditions, the digital display shows an error code and
the red LED turns on
Description of LED and Digital Display Codes
LED
Digital Display
Description
Green
13.5
Example: 13.5 Volts
Green
0.25
Example: 0.25 kW (250 Watts)
Red
E01
Under voltage alarm/shutdown
Red
E02
Over voltage shutdown
Red
E03
Over load shutdown
Red
E04
Over temperature shutdown
Red
E10
Short circuit or output overheat
Table A.1
: LED and Digital Display Codes
Operating Limits: Input Voltages
Operating Condition
Voltage Range
Comment
Normal
10.5 - 15.5 V
N/A
Peak Performance
13 - 14.5 V
N/A
Low Voltage Alarm
< 11.0 V
Alarm sounds
Low Voltage Shutdown
< 10.5 V
Unit shuts down
High Voltage Shutdown
> 15.5 V
Unit shuts down
Low Voltage Shutdown Restart
11.5 V
Unit will restart
Table A.2
: Voltage Operating Limits
After a shutdown, restart the system by turning the device off and letting the unit
cool down for 15 minutes before turning the device back on