59 

 

6. Load icon, there will be lighting effects in the bulb when there is an output to the 
load 
7. Charge LED (refer to the table below) 
8. Output LED (refer to the table below) 
9. Button interface 

 

Enter: Press this button to enter setup interface or switch between programs  

 

Up arrow: Use this to increase parameter values by increments of 0.1 

 

Down arrow: Use this to decrease parameter values by increments of 0.1 

 

Esc: Press this button to exit the setup interface and save the modified 
parameters 

 

 

Table A.4

: LED Reference

 

 

Maintenance 

1.

 

Clean the exterior of the unit with a damp cloth periodically to prevent the 
accumulation of dust and dirt 

2.

 

Ensure that the terminal screws for the wires are not loose 

3.

 

Ensure that the voltage of the battery is around 12 volts  

4.

 

Ensure that the float voltage is around 13.8 volts 

 

Figure A.11

: Float Voltage Reference

 

 

5.

 

Ensure that the under voltage is around 10.8 volts  

Содержание Solar Classic 150

Страница 1: ...light Volts 4 Press Enter 5 Make sure the Equalize Absorb and Float voltages are 30 6 V 29 2 V and 27 0 V respectively Figure A 1 Programmed Voltage Settings 6 If the voltages do not match up highligh...

Страница 2: ...the programmed time is not two hours scroll to the right and highlight the time under EQ 7 Adjust the equalizing time using the up and down arrow keys 8 Press Enter to save the time 9 Press Status to...

Страница 3: ...inside the breaker box next to the kitchen door Figure A 4 Kitchen Freezer and Lights Circuit Breakers 3 Turn off the circuit breakers for the solar panel and the charge controller connections inside...

Страница 4: ...when EQ Started is highlighted Figure A 6 Equalization Start Interface 8 Press Status to return to home screen 9 On the home screen the bottom right corner should say EQ 10 To stop a manual equalizati...

Страница 5: ...n the inverter 2 Press the power switch button for one second to turn off the inverter 3 If you are not planning on recharging the battery within a week or so turn the inverter off 2 Indicator LEDs 1...

Страница 6: ...e shutdown Red E03 Over load shutdown Red E04 Over temperature shutdown Red E10 Short circuit or output overheat Table A 1 LED and Digital Display Codes Operating Limits Input Voltages Operating Condi...

Страница 7: ...e power should turn off For example if the lamp goes out it is functioning correctly If the lamp remains lit or the reset button does not pop out the GCFI may not be functioning If the GCFI trips by i...

Страница 8: ...56 Figure A 9 Power Inverter DC Terminals...

Страница 9: ...utdown Reduce load E04 with heavy load connected Over temperature shutdown Cool down inverter and reduce load E04 with normal load connected Over temperature shutdown Improve ventilation E10 no output...

Страница 10: ...influence on functionality 3 Digital display of the battery voltage 4 Represents the wind turbine providing power generation if there is a solar panel connected there will be a solar panel icon 5 Rep...

Страница 11: ...this to decrease parameter values by increments of 0 1 Esc Press this button to exit the setup interface and save the modified parameters Table A 4 LED Reference Maintenance 1 Clean the exterior of t...

Страница 12: ...60 Figure A 12 Under Voltage Reference 6 Ensure that the over voltage is around 15 0 volts Figure A 13 Over Voltage Reference...