M
IDIAN
E
LECTRONICS
I
NCORPORATED
P
AGE
13
Function Bits:
00
5.5.4.9.8 Profile 8
The factory default settings for this profile are as
follows:
Profile Name:
QUICK
CALL
1
Pager Type:
2-Tone
Format:
AVCALL/QC1
2+2
1
st
Tone Time:
1000
2
nd
Tone Time:
1000
5.5.4.9.9 Profile 9
The factory default settings for this profile are as
follows:
Profile Name:
GE
2-TONE
Pager Type:
2-Tone
Format:
GE
1
st
Tone Time:
1000
2
nd
Tone Time:
1500
5.5.4.9.10 Profile 10
The factory default settings for this profile are as
follows:
Profile Name:
PLECTRON-FAST
Pager Type:
Any
2-Tones
1
st
Tone Time:
0750
2
nd
Tone Time:
0250
5.5.5 RADIO SETUP menu
5.5.5.1 Keyup Delay setting
This sets the
Key-Up Delay
, also known as
Front
Porch Time
. This is the amount of time the PDE will
wait after asserting PTT before sending tones over the
air. This time allows for delays introduced by repeaters
and decoding of squelch control signals such as
CTCSS.
Range:
01 to 99 * 100 milliseconds
Default:
04 * 100 milliseconds
5.5.5.2 COR
Polarity
setting
Note:
If not using the
Busy Lockout
feature, you may
leave the COR input unconnected.
The COR input is used in conjunction with the
Busy
Lockout
feature. Change this setting to match the
state of the COR (carrier detect) input when the radio
channel is busy.
LOW
Channel is busy when COR is 0V.
HIGH
Channel is busy when COR is 5V.
5.5.5.3 Busy Lockout feature
This feature prevents the PDE from transmitting on a
busy channel. If this feature is ON, the unit will not
transmit when the COR input is in the active state.
When making a call and the channel is busy, the PDE
will wait until the channel is clear and then transmit.
New calls cannot be placed until the pending call is
completed or canceled. When this option is OFF, the
unit will transmit regardless of the state of the COR
input.
OFF
Transmit regardless of COR input.
ON
Do not transmit when channel busy.
5.5.6 SECURITY
SETUP
menu
5.5.6.1 Security
setting
Allows the security option to be turned on and off. If
turned off, the
LOCK/UNLOCK
menus will not appear.
OFF
Disable security feature.
ON
Enable security feature.
5.5.6.2 Password
setting
Sets the password required to UNLOCK the menu
system when the Security is turned on. Must be 4
numeric digits.
Range:
4 digits
Default:
0000
5.5.7 UTILITIES
menu
5.5.7.1 Reset
Defaults
This will reset all the parameters listed above to the
factory default settings. The contents of the user
database will not be affected.
5.5.7.2 Clear
Database
This will completely clear the user database. The
contents of the other parameters listed above will not
be affected.
5.5.7.3 Factory
Debug
This is used by the factory for product testing.
Do not
select this function unless directed to do so by
Midian Technical Support.
6 APPENDIX
6.1 S
YSTEM
E
RROR
M
ESSAGES
CHANNEL BUSY
Reason:
An attempt was made to transmit or make a
call on a busy channel with busy lockout enabled.
Solution:
Wait until the channel is clear before
transmitting.
DATABASE EMPTY
Reason:
An attempt was made to edit or delete a user
Содержание PDE-1