background image

P

AGE 

8  

M

IDIAN  

E

LECTRONICS  

I

NCORPORATED

 

 

 

Code of the unit you wish to call. 

Direct Alphanumeric Entry mode – 

Key in the User 

Name as it appears in the user database. 

Numeric Select mode – 

Press the right <SCROLL> 

button to enter select mode. Now you can use both left 
and right <SCROLL> buttons to select a CAP code 
from the database. Also, you may enter a partial CAP 
code prior to pressing right <SCROLL> to find the 1

st

 

entry in the database matching the partial code. 

Alphanumeric Select mode – 

Press the right 

<SCROLL> button to enter select mode. Now you can 
use both left and right <SCROLL> buttons to select a 
CAP code from the database. Also, you may enter a 
partial name prior to pressing right <SCROLL> to find 
the 1

st

 entry in the database matching the partial name. 

Remember, you can use the <*> to toggle between 
numeric and alphabetic entry modes. Press <SEND> 
to make the call. When sending to a POCSAG pager, 
you will then be prompted for a numeric or 
alphanumeric message. Entering a message may be 
done in several ways. 

5.1.1  POCSAG Message Entry 

Numeric Entry mode – 

Simply key in the numeric 

message up to 14 digits. 

Alphanumeric Entry mode – 

Key in an alphanumeric 

message up to 25 characters.  

Select mode – 

Press the right <SCROLL> button to 

enter select mode. Now you can use both the left and 
right <SCROLL> buttons to select a message from the 
list of 10 ‘pre-canned’ messages in the Saved 
Messages list. 

Press <SEND> after message entry to place the page. 

Note:

 Numeric POCSAG pagers can decode the 

following special non-numeric characters: space ? U - [ 
]. Alphanumeric entry mode is required to enter these 
special ‘numeric’ characters. Note that the U character 
is typically understood to mean ‘urgency’. 

Press <#> to escape the Call mode and return to the 
Main Menu. 

 

5.2 LOCK

 OR 

UNLOCK

 COMMAND

 

Note

 The LOCK and UNLOCK menu options do not 

appear unless enabled in 

SECURITY SETUP

.  

Selecting LOCK will disable access to the parts of the 
menu system described in the following sections. 
Select UNLOCK to enable the entire menu system. 
You must enter a 4-digit password to unlock the menu 
system. See 

SECURITY SETUP

 for more information.  

 

5.3 USERS

 MENU

 

5.3.1 Add 

User 

menu 

Allows the system administrator to add a new user to 
the database. When ADD USER is selected, you will 

be prompted to fill in the information for that user such 
as User Name and CAP Code. See 

EDIT USER

 for 

more information. 

5.3.2  Delete User menu 

Allows you to delete a user record from the database. 
When DELETE USER is selected, you will be able to 
select the user you wish to delete in the same manner 
as if placing a call to a unit. Use the scroll buttons to 
find the user you wish to delete. Press <SEND> to 
delete the selected user. You will have to press 
<SEND> a second time to confirm. Press <#> to 
cancel if you change your mind. 

5.3.3  EDIT USER menu 

Allows you to change information about a user. Select 
the user you wish to edit in the same manner is if 
placing a call to that user. Use the scroll buttons to find 
the user you wish to edit. Press <SEND> to edit the 
information for the selected user. 

You will be prompted to fill out each field in turn. After 
entering the data for a field, press <SEND> to go on to 
the next field. To leave a field unchanged, simply press 
<SEND> without entering data. 

5.3.3.1 User 

Name 

field 

This alphanumeric field contains the name of the user 
associated with a unit. A maximum of 14 characters 
may be used. A name already in the database will not 
be accepted. See the 

Data Entry

 section for more 

information. 

Range: 

0-14 characters 

Default:

 blank 

5.3.3.2  Pager Profile setting 

Select from among the 10 pager profiles by name 
using the <SCROLL> buttons. 

Range: 

0-14 characters 

Default: 

N/A 

5.3.3.3  CAP Code field or Frequency fields 

If the pager type is 2-tone, 5-tone, DTMF, or POCSAG, 
You will be prompted for a numeric CAP code to be 
associated with the unit. If using AVCALL, see the 
section 6.2.1 for entry instructions. If using Motorola 
Quick Call 1 (2+2), see section 6.2.2 for entry 
instructions. 

Range: 

1-10 digits depending on pager format 

Default: 

blank 

If the pager type is ‘any 2-tone’ you will be prompted to 
enter two 5-digit frequencies. The 1

st

 digit is the 1000’s 

place and the last the 1/10’s place. For example 615.8 
Hz is entered as 06158, 1985.0 Hz is entered as 
19850. Technically, you can enter anything from 
0000.0 to 9999.9 Hz, however the practical maximum 
is about 3000.0 Hz.  

Range: 

5 digits 

Содержание PDE-1

Страница 1: ...pager formats simultaneously 155 entry alias database Two tone formats include Motorola GE Reach Send any arbitrary 2 tones for Plectron Generates POCSAG Supports DTMF and several 5 tone formats Easy...

Страница 2: ...uts Output Level TX unloaded 150 2500 mV p p Output Impedance TX 27k with jumper JU 4 cut Mechanical Dimensions 2 H x 6 W x 8 L Operating Temp 0 to 50 C Encode Formats AVCALL GE REACH MOTOROLA QUICK C...

Страница 3: ...NTS 4 4 OPERATION 5 4 1 BASIC OPERATION 5 4 2 CALLING A UNIT 6 4 3 USER DATABASE 6 4 4 SPEED DIAL FEATURE 7 4 5 SAVED MESSAGES FEATURE 7 4 6 SECURITY FEATURE 7 5 MENU SYSTEM 7 5 1 CALL A UNIT COMMAND...

Страница 4: ...that positive is connected to the center pin inside sleeve GROUND P1 6 Black Connect to radio ground AUDIO INPUT RX IN P1 8 Blue This connection is only required if you wish to hear radio audio throu...

Страница 5: ...CROLL INDICATORS An arrow appearing on either side of the display indicates more choices are available by pressing the corresponding SCROLL button SEND Button Selects the item shown on the display Pre...

Страница 6: ...aker so you can hear the paging tones go out Select CALL A UNIT from the Main Menu Type in 3 digits and press SEND You should hear a 1 second tone followed by a 3 second tone You have just sent a Moto...

Страница 7: ...ode but with numbers 4 4 SPEED DIAL FEATURE When the speed dial feature is enabled you can simply press and hold any of the digits 0 9 for 1 5 seconds to place a call when in Call Mode only First you...

Страница 8: ...or more information 5 3 USERS MENU 5 3 1 Add User menu Allows the system administrator to add a new user to the database When ADD USER is selected you will be prompted to fill in the information for t...

Страница 9: ...eature The speed dial entries 0 9 correspond to the number keys 0 9 To associate a unit to a speed dial number it must be in the user database For each speed dial simply locate the user in the databas...

Страница 10: ...ion beeps can still be heard If it is desired that absolutely no sound be heard from the console speaker simply disconnect it from the main circuit board OFF Internal speaker disabled ON Internal spea...

Страница 11: ...field Enter the duration of the 1st tone in milliseconds For EIA pagers this is typically 33 milliseconds All 4 digits must be entered Range 0000 to 9999 milliseconds 5 5 4 4 3 Nth Tone Time field En...

Страница 12: ...ollowing shows the factory default pager profile settings that allow the PDE to function out of the box Please refer to section 4 2 1 for more information 5 5 4 9 1 Profile 1 The factory default setti...

Страница 13: ...smitting on a busy channel If this feature is ON the unit will not transmit when the COR input is in the active state When making a call and the channel is busy the PDE will wait until the channel is...

Страница 14: ...is not likely to happen unless non standard encode timings and encode lengths are used It is also possible that there could be a hardware failure Solution If total time of the key up delay and signali...

Страница 15: ...tone formats in that the CAP code consists of alphabetic characters instead of numbers To overcome this AVCALL CAP codes must be entered as 2 digits per letter A total of 8 digits must be entered Refe...

Страница 16: ...5 LB 0851 1 36 MB 0944 1 37 CB 0371 5 38 NB 1047 1 39 PB 1161 4 Z SERIES 40 DZ 0384 6 41 EZ 0426 6 42 FZ 0473 2 43 GZ 0524 8 44 HZ 0582 1 45 JZ 0645 7 46 KZ 0716 7 47 LZ 0794 3 48 MZ 0881 0 49 CZ 0346...

Страница 17: ...Charts The following REACH 2 tone information is provided for your convenience 6 2 7 5 6 tone Chart The following 5 6 tone information is provided for your convenience 6 2 8 Pager Timing Charts The fo...

Страница 18: ...PAGE 18 MIDIAN ELECTRONICS INCORPORATED 6 3 MENU SYSTEM MAP...

Страница 19: ...OC64 PIC6501 PIC6502 COC65 PIC6601 PIC6602 COC66 PIC6701 PIC6702 COC67 PIC6801 PIC6802 COC68 PIC6901 PIC6902 COC69 PIC7001 PIC7002 COC70 PIC7101 PIC7102 COC71 PIC7201 PIC7202 COC72 PIC7301 PIC7302 COC...

Страница 20: ...This page intentionally left blank...

Страница 21: ...801 COR58 PAR5902 PAR5901 COR59 PAR6002 PAR6001 COR60 PAR6102 PAR6101 COR61 PAR6202 PAR6201 COR62 PAR6302 PAR6301 COR63 PAR6402 PAR6401 COR64 PAR6502 PAR6501 COR65 PAR6602 PAR6601 COR66 PAR6702 PAR670...

Страница 22: ...C O t b 0 s c h 2 P A V O 2 0 1 P A V O 2 0 2 PAVO2013 PAVO2012 PAVO2011 PAVO2010 PAVO209 PAVO208 PAVO207 PAVO206 PAVO205 PAVO204 PAVO203 C O V O 2...

Страница 23: ...COLED1 1 PILED102 PILED103 COLED1 2 PILED201 PILED202 COLED2 1 PILED202 PILED203 COLED2 2 PIP601 COP6 1 PIP602 COP6 2 PIP603 COP6 3 PIP604 COP6 4 PIP605 COP6 5 PIP606 COP6 6 PIP607 COP6 7 PIP608 COP6...

Страница 24: ...This page intentionally left blank...

Страница 25: ...4B01 PAR34B02 COR34B PAR54A01 PAR54A02 COR54A PAR54B02 PAR54B01 COR54B PAR77A01 PAR77A02 COR77A PAR77B02 PAR77B01 COR77B PAR9802 PAR9801 COR98 PAR9901 PAR9902 COR99 PAR10002 PAR10001 COR100 PAR10101 P...

Страница 26: ...A S W 7 0 0 P A S W 7 0 2 P A S W 7 0 1 C O S W 7 P A S W 8 0 0 P A S W 8 0 2 P A S W 8 0 1 C O S W 8 P A S W 9 0 0 P A S W 9 0 2 P A S W 9 0 1 C O S W 9 P A S W 1 0 0 0 P A S W 1 0 0 2 P A S W 1 0 0...

Отзывы: