DDU-300 Manual Rev. 2006.02.22

 

1 S

PECIFICATIONS

 

Voltage/Current 
Operating Voltage (nominal)  ...............................12 VDC 
Operating Voltage (min-max)  .........................12-15 VDC 
Operating Current (standby @12 VDC) ................ 100 mA 
Operating Current (peak @15 VDC)..................... 500 mA 

Inputs 
Input Level (RX) .................................... 100-3000 mV p-p 
Input Impedance (RX) ...........................................> 10k

 

Outputs 
Output Level (TX, unloaded) ................. 150-2500 mV p-p 
Output Impedance (TX)...........................  27k

 if JU4 cut 

Speaker Audio Output ................................... 1 W into 8

 

Mechanical 
Dimensions: .................................. .2

"H x 6½W x 8¾"L 

Operating Temp ..............................................0° to 50° C 
 
Decode Format 
MIdian’s TVS-2 Kryptic format (4-digit) 

Other 
ANI Recall Stack Size  ................................................ .10  
Alias Database Size  ................................................. .137 
 
 

 

WARRANTY 

 

Midian Electronics, Inc., warrants this product to be 
free from defects in material and workmanship for 
two years from date of shipment. If such malfunction 
occurs, it will be repaired or replaced (at our option) 
without charge for materials or labor if returned to the 
factory. This warranty does not apply to any parts 
damaged due to improper use--including accident, 
neglect, unreasonable use, and improper installation--
or to unauthorized alterations or modifications of the 
equipment. It does not extend to damage incurred by 
natural causes such as lightning, fire, floods, or other 
such catastrophes, nor to damage caused by 
environmental extremes, such as power surges 
and/or transients. It does not extend to 
microprocessors, if it is determined by Midian that the 
failure of a micro is due to static damage, application 
of improper voltages to the unit, or other problems not 
related to circuit design. In such case or in the case of 
a desire to update the micro to a different version of 
software, such request must be specified in writing, 
and there will be a charge agreed upon by both 
parties. 
This product is warranted to meet published 
specifications and to operate as specified only when 
properly installed in radio equipment which complies 
with U.S. FCC specifications and the applicable radio 
manufacturer's specifications. Midian Electronics is 
not responsible for any operational problems caused 
by system design, outside interference, or improper 
installation. 

Equipment for repair can be returned to the factory 
without prior written authorization. A brief letter 
describing the nature of the defect should be included 
with the merchandise. Repair by other than Midian 
Electronics, Inc., will void this warranty. In-warranty 
merchandise must be shipped, freight prepaid, to 
Midian Electronics. Midian Electronics will return, 
freight prepaid via UPS ground, the repaired or 
replaced equipment to purchaser, within the United 
States. Out-of-warranty repairs will be billed at the 
rate of $60 per hour, plus replacement parts. 
This warranty applies to the original purchaser of the 
equipment only. Midian Electronics is not liable under 
this warranty, or any implied warranty, for loss of use 
or for other consequential loss or damage 
experienced by the purchaser. Some states do not 
permit the exclusion or limitation of implied warranties 
or consequential damages. This warranty provides 
special legal rights, and the purchaser may have 
other rights that vary from state to state. 
Copyright Notice 
The information in this manual and any software in 
this product remain the property of MIDIAN 
ELECTRONICS, INC. Reproduction, duplication, or 
disclosure is not permitted without the prior written 
consent of MIDIAN ELECTRONICS, INC. 

 

Содержание DDU-300

Страница 1: ...N MANUAL Model Features 10 entry ANI recall memory 137 entry alias database Auto mute leading ANI Alternate function as a repeater access controller Decodes Midian s TVS 2 Kryptic 4 digit ANI s 11 sta...

Страница 2: ...version of software such request must be specified in writing and there will be a charge agreed upon by both parties This product is warranted to meet published specifications and to operate as specif...

Страница 3: ...2 JUMPER SETTINGS 5 3 3 ADJUSTMENTS 5 3 4 CONFIGURATION SETTINGS 5 4 BASIC OPERATION 5 4 1 DISPLAY MODE 5 4 2 MENU MODE 6 4 3 USER DATABASE 7 4 4 MISCELLANEOUS FEATURES 7 5 MENU SYSTEM 8 5 1 CALL COMM...

Страница 4: ...n the squelch output to the radio is asserted AUDIO OUTPUT TX OUT P1 4 Green Connect to the mic hi input of the radio The output impedance of the DDU can be adjusted if necessary by replacing leaded r...

Страница 5: ...g down the SEND key Speak loudly into the microphone at a normal distance Adjust R105 such that maximum system modulation is achieved at peak voice SPEAKER PRE AMP Though the DDU has a volume control...

Страница 6: ...mode with the last ANI received being shown MONITOR This button always controls the monitor function of the radio Press MONITOR to toggle the state of the monitor output to the radio SEND Activates t...

Страница 7: ...ven when switched off 4 3 2 Setting Up the User Database Begin by compiling a list of names and ID numbers Give some thought on how you are going to abbreviate the names since only 14 characters per n...

Страница 8: ...t or units You will be given the option to enter the 4 digit numeric ID of the unit you wish to call If the user database is set up you may use the right SCROLL buttons to go into Select Mode and find...

Страница 9: ...you change your mind 5 5 ADMIN MENU 5 5 1 Set Key 1 setting Allows you to modify security key code 1 The key is sent when one of the Prog Key s command is issued All 8 digits must be entered Range 8 d...

Страница 10: ...ts Range 00 23 Default 00 5 6 2 2 Minute setting Set the minutes past the hour Enter two digits Range 00 59 Default 00 5 6 3 CONSOLE SETUP menu 5 6 3 1 Data Entry Mode setting Determines if numeric en...

Страница 11: ...ting on a busy channel If this option is ON the unit will not transmit when the COR input is in the active state The DDU will wait until the channel is clear and then transmit When this option is OFF...

Страница 12: ...is a status message for each of the digits 0 through 9 These correspond to the first digit of a status location packet sent by the TVS 2 Emergency packets always begin with the digit 9 and thus status...

Страница 13: ...ory default settings The contents of the user database will not be affected 5 6 8 2 Clear Database This will clear the user database of all ID s and User Names The contents of the other parameters lis...

Страница 14: ...SUM ERR Reason The configuration settings stored in EEPROM have been corrupted This can happen if power is lost at the exact time a parameter is being updated All configuration settings will be set ba...