Midea WWK08CW71E Скачать руководство пользователя страница 7

6

INSTALLATION  INSTRUCTIONS

SECURE THE ACCORDION PANELS

4

4

B. Slide the free end "

" section of the panel directly 

     into the cabinet as shown in Fig. 2. Slide the panel 
     down. Be sure to leave enough space to slip the 
     top and bottom of the frame into the rails on the 
     cabinet.

Fig.2

"

"section

C.  Once the panel has been installed on the side of 
      the cabinet, make sure it sits securely inside the 
      frame channel by making slight adjustments. 
      Slide the top and bottom ends of the frame into the
      top and bottom rails of the cabinet. Fig.3.

D.  Slide the panel all the way in and repeat on the 
      other side. 

Top Rail

Bottom Rail

Fig.3

A.Keep a firm grip on the air conditioner, carefully
place the unit into the window opening so the bottom
of the air conditioner frame is against the window
sill (Fig.5). Carefully close the window behind the top
rail of the unit.
         

Fig.5

NOTE: 

Check that air conditioner is tilted back about

O

H  (Fig.5) (tilted  about  3 t o 4  downward t o th

  e o utside).

  After proper installation, condensate should not drain 
  from the overflow drain h

  ole d

  uring  normal u se,c orrect  

  the slope otherwise. 

  
  

O  

B.Extend the side panels out against the window
frame (Fig.6).
         

window
frame

Fig.6

INSTALL SUPPORT BRACKET

5

5

A.Place the frame lock between the frame 
extensions and the window sill as shown(Fig.7). 
Drive 3 / 4   (19mm)or 1

locking screws 

through the frame lock and into the sill .

NOTE

: To prevent window sill from splitting,drill 

1 / 8"  (3mm) pilot holes before driving screws.
         

 / 2 "(12.7mm) 

"

Fig.7

NOTE:

 If storm window blocks AC, see Fig. 11.

Top Rail

Bottom Rail

Top left

Top right

Fig.4

Wooden Windows

INSIDE

OUTSIDE

H:About 3/4  to 1 

for 5 to 8K);

Measure from the cabinet edge

3

H:About 1  to 1 /

for 10 to12K);

8

H

Содержание WWK08CW71E

Страница 1: ...ly and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR...

Страница 2: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Страница 3: ...contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation brac...

Страница 4: ...n removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils The complete electical rating of your new room air condition...

Страница 5: ...o not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special...

Страница 6: ...CORDION PANELS 3 3 NOTE Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of 5 16 This is necessary for proper condensed water utilization and drainage If you...

Страница 7: ...ner frame is against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about O H Fig 5 tilted about 3 to 4 downward...

Страница 8: ...e optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1 After the unit is installed to the window measure the inner width of t...

Страница 9: ...lock Remove the R1 Panel and close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit...

Страница 10: ...ing or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pingi...

Страница 11: ...ooling Starts Timer auto start stop feature Set the auto start stop unit time no matter what the unit is on or off Turning the unit ON or OFF at any time will cancel the Auto Start Stop timed program...

Страница 12: ...hake excess water from the filter Be sure the filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Take down the low front panel Low front panel Take out the...

Страница 13: ...coil set FAN ONLY mode Compressor stopped when changing modes Wait for 3 minutes after set to the COOL mode 12 Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Unit...

Страница 14: ...Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too l...

Страница 15: ...Midea...

Страница 16: ...90 90 90...

Страница 17: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: