INSTALLATION  INSTRUCTIONS

    Read these instructions completely
    and carefully.

IMPORTANT- 

Save these

instructions for local inspector s use.

IMPORTANT- 

Observe all

governing codes and ordianaces.

Note to Consumer

Keep these

instructions for futrue reference.

Note to Installer

Be sure to leave these

instructions with the Consumer.

Completion time

Approximately 1 hour.

We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.

    BEFORE YOU BEGIN

Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.

CAUTION

Do not change the plug on the power cord
of the air conditioner.
Aluminum house wiring may present special
problems- consult a qualified electircian.

When handling unit, be careful to avoid cuts from
sharp metal edges and aluminum fins on front and
rear coils.

TOOLS YOU WILL NEED

Screwdriver

Level

TOOLS YOU MAY USE

Screwdriver

Pencil

Ruler or tape measure

Scissors or knife

Save Carton and these Installation Instructions
for future reference. The carton is the best way
to store unit during winter, or when not in use.

NOTE:

H

Your air conditioner is designed to install in 
standard double hung windows with opening 
widths of 23 to 36 inches(584mm to 914mm) .

WINDOW REQUIREMENTS

Model

H

5000~8000Btu/h

10000~12000Btu/h

14 (356mm)

15-1/2 (394mm)

Table 1

Skill level

Installatio o 

f this appliance

requires basic mechanical skills.

Содержание WWK08CW71E

Страница 1: ...ly and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR...

Страница 2: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Страница 3: ...contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation brac...

Страница 4: ...n removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils The complete electical rating of your new room air condition...

Страница 5: ...o not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special...

Страница 6: ...CORDION PANELS 3 3 NOTE Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of 5 16 This is necessary for proper condensed water utilization and drainage If you...

Страница 7: ...ner frame is against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about O H Fig 5 tilted about 3 to 4 downward...

Страница 8: ...e optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1 After the unit is installed to the window measure the inner width of t...

Страница 9: ...lock Remove the R1 Panel and close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit...

Страница 10: ...ing or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pingi...

Страница 11: ...ooling Starts Timer auto start stop feature Set the auto start stop unit time no matter what the unit is on or off Turning the unit ON or OFF at any time will cancel the Auto Start Stop timed program...

Страница 12: ...hake excess water from the filter Be sure the filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Take down the low front panel Low front panel Take out the...

Страница 13: ...coil set FAN ONLY mode Compressor stopped when changing modes Wait for 3 minutes after set to the COOL mode 12 Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Unit...

Страница 14: ...Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too l...

Страница 15: ...Midea...

Страница 16: ...90 90 90...

Страница 17: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Отзывы: