Service manual, 2016-12
30
/
42
sensor fail
Step2:change the main PCB
Step3:change the display PCB
E9
F room high
temp alarm
E9
Check the temperature of F room and check whether the
door seal fan motor and compressor of F room operate
normally
9.9
Defrosting function
1.Defrost the freezing chamber as per the accumulative operation time of the Compressor2.If power
failure occurs abruptly to the Compressor and the defrosting sensor in freezing chamber is less than 0
o
C
after powering on, then first conduct defrosting once. If more than 0
o
C
, then defrosting is not needed.
3.After that, conduct defrosting according to using condition and ambient temperature in a period
between 6 and 24 hours as per the accumulative operation time of the Compressor.
9.10
Test mode
Mandatory Defrost
1)
enter into
Press the button both“
∧
”and “
∨
”for 3senconds, it will enter into mandatory defrost, the display
panel will display figure “3”
If the defrosting sensor failure happen, the heater will work 20 minutes, then turn off,. If the defrosting
sensor failure happen during the defrosting, the heater only work 3 minutes after that, then turn off
2)
Exit
★
exit manually: under the state of mandatory defrost, press both button both “
∧
”and “
∨
” for 3
seconds, it will exit the mandatory defrost after 3 minutes
★
Exit automatically : defrost for 3 minutes ,then judge the exiting condition for exiting.
3) working state, same as the normal defrosting
9.11
Self-diagnosis
Entry condition
With 3 seconds after power on, if there is no sensor failure and the actual measured temperature ≥
0
℃
, it will enter into self-diagnosis
Process of Self-diagnosis
1. Switch on the defrosting heater for 5 seconds, then switch off for 5 seconds
2. Switch on the fan motor for 5 seconds, then switch off for 5 seconds
3. turn on the fan motor and compressor at same time
4.it will exit the self-diagnosis after 20 minutes.
If there is sensor failure happen, it will exit the Self-diagnosis immediately
Содержание UL-BD386WE-SQ
Страница 5: ...Service manual 2016 12 5 42 1 Safety Warning Code 1 1Warning for operation safety ...
Страница 6: ...Service manual 2016 12 6 42 ...
Страница 7: ...Service manual 2016 12 7 42 ...
Страница 8: ...Service manual 2016 12 8 42 1 2Safety instruction for refrigerant ...
Страница 11: ...Service manual 2016 12 11 42 3 5Change the door opening direction None 3 6 Installation of handle ...
Страница 15: ...Service manual 2016 12 15 42 ...
Страница 17: ...Service manual 2016 12 17 42 Down view Open Door Maximum open angle of door 135o ...
Страница 34: ...Service manual 2016 12 34 42 11 Troubleshooting Method 11 1 No refrigeration ...
Страница 35: ...Service manual 2016 12 35 42 11 2 Compressor failure ...