4
Remote control
Turn on/off
the oscillating
button
On/ standby button
Funtion button
Button of temperature increase
Timing button
(AAA battery 1.5V)
Power assembly
drawing
Button of temperature
decrease
ECO button
Control range of remote controller
The remote controller control can be normally
used within 5 meters in front of the product
and in the left and right angles of 30 degrees.
Please use a manganese or alkaline battery
of type "AAA" and do not use a non-recycla
-
ble battery.
Oscillation function
The electric heater in operation mode, press the "Oscillation" key to open the
oscillation function, pressing this button to turn off the oscillation function; when
the electric heater stops heating function, the wind oscillating function also stop.
Temperature sensor short circuit, open circuit protection function
No matter in what mode, the temperature sensor appears short circuit or open
circuit, digital screen displays "E1" or "E2" and constantly flicker, while any key
operation is invalid and the buzzer rings 10 times.
Safety protection
In the start state, when the room temperature TH is above 122°F, close all
outputs system, The digital screen displays "FF" and flashes 1 time per second
at a frequency of 75 times, press any key will not work, only the power down to
exit the protection.
Tip-over switch
As a safety measure, the unit will shut off automatically if it is
knocked over. Should this occur, simply turn the heater off and stand it back up
to a regular upright posit ion, then switch it back on.
ECO energy saving function
Select the ECO energy saving gear and set the temperature. The heater will
adjust its heating gear by comparison between the ambient temperature and set
temperature.
Remote controller
Use of the remote controller: the key functions are basically the same as the
body operation panel.