background image

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding plug
and current detection device

Grounding type wall
receptacle

WARNING

NOTE:

The power supply cord with this air 
conditioner contains a current detection 
device designed to reduce the risk of fire.
Please refer to the section Operation
of Current Device for details.In the event 
that the power supply cord is damaged, 
it cannot be repaired-it must be replaced 
with a  cord  from  

the  

Product  

Manufacturer.  

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. 
Do not remove any prong from the power 
cord. 

WARNING

For Your Safety

WARNING

Prevent Accidents

WARNING

Electrical Information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity  
of this or any other appliance.

Operation of Cur rent Device

(Applicable to the unit adopts current detection 
device only )

The power supply cord contains a current device that senses 
damage to the power cord. To test your power supply cord do 
the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug 
    head. Press the TEST button, you will notice a click as the 
    RESET button pops out.
3. Press the RESET button, again you will notice a click as 
    the button engages.
4. The power supply cord is now supplying electricity to the 
    unit. (On some products this it also indicated by a light on 
    the plug head.)

3

To reduce the risk of fire, electrical shock, or injury to persons when using your
air conditioner, follow basic precautions, including the following:
    Be sure the electrical service is adequate for the model you have chosen. This
    information can be found on the serial plate, which is located on the side of the
    the cabinet and behind the grille.
    If the air  conditioner  is  to  

be  

installed  

in  

a  

window,  

you  

will  

probably  

want  

to  

clean  

    both sides of  the  glass  first.  

If  

the  

window  

is  

a  

triple-track  

type  

with  

a  

screen  

panel

    included, remove the screen completely before installation.
    Be sure  the  air  conditioner  has  

been  

securely  

and  

correctly  

installed  

according  

to

    the installation instructions in this manual. Save this manual for possible future
    use in removing or installing this unit.
    When handling the  air  conditioner,  be  careful  to  avoid  cuts  from  sharp  metal  fins
    on front and rear coils. 
   

The complete electical rating of your new room air conditioner is stated on the 
serial plate. Refer to the rating when checking the electrical requirements.
     Be sure the air conditioner is properly grounded. To minimize shock and fire 
     hazards, proper grounding is important. The power cord is equipped with a 
     three-prong grounding plug for protection against shock hazards.
     Your air conditioner must be used in a properly grounded wall receptacle. If the 
     wall receptacle you intend to use is not adequately grounded or protected by a 
     time delay fuse or circuit breaker, have a qualified electrician install the proper 
     receptacle. Ensure the receptacle is accessible after the unit installation.
     Do not run air conditioner without side protective cover in place.This could 
     result in mechanical damage within the air conditioner.
     

Do not use an extension cord or an adapter plug.

IMPORTANT SAFETY INSTRUCTIONS

    Do not use this device to turn the unit on or off.
    Always make sure the RESET button is pushed in for 
    correct operation.
    The power supply must be replaced if it fails reset when 
    either the TEST button is pushed, or it cannot be reset. A 
    new one can be obtained from the product manufacturer.
    If power supply cord is damaged, it cannot be repaired. It 
    MUST be replaced by one 

 

obtained from the product 

    manufacturer.

NOTE:

NOTE:

This air conditioner is designed to be operated 

            under condition as follows:

Cooling 
operation

Outdoor temp: 

Indoor temp: 

Heating 
operation

Outdoor temp: 

23-76 F/

C

O

O

-5-24

Indoor temp: 

32-80 F/

O

0-27 C

O

64-109 F/18-43 C (64-125 F/18-52 C 
for special tropical models)

O

O

O

O

62-90 F/

O

17-32 C

O

Note: Performance may be reduced outside of these 
operating temperatures.

Содержание MW06DRWBA1RCM

Страница 1: ...210 285 80g...

Страница 2: ...al carefully and keep it for future reference WINDOW TYPE ROOM AIR CONDITIONER TABLE OF CONTENTS Installation Instructions 24 10 23 Normal Sounds Important Safety Instructions 1 9 Troubleshooting Tips...

Страница 3: ...eat generation excess It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Страница 4: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Страница 5: ...he window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the in...

Страница 6: ...of the person competent in the use of flammable refrigerants DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with other electrical ap...

Страница 7: ...hecks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimised For repair to the refrigerating syst...

Страница 8: ...sence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position...

Страница 9: ...not be used The following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the s...

Страница 10: ...ressure tested with OFN The system shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site Before carrying out th...

Страница 11: ...if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recov...

Страница 12: ...this manual are for explanation purpose only The air conditioner you have may be slightly different The actual shape shall prevail NOTE INSTALLATION INSTRUCTIONS NOTE The unit you purchased may be loo...

Страница 13: ...in these instructions when installing this air conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on t...

Страница 14: ...h models only Fig C NOTE The top rail hardware and the Fig A Fig B and Fig C are not applicable to the units more than 10000Btu h Before installing unit the top rail must be assembled on the unit For...

Страница 15: ...against the window sill Fig 5A and Fig 5B Carefully close the window behind the top rail of the unit Fig 5A If storm window blocks AC see Fig 11 NOTE Top Rail Bottom Rail Top left Top right Fig 4 Woo...

Страница 16: ...frame lock and frame extensions into the windows sash as shown Fig 8B Fig 8A Fig 8B C To secure lower sash in place attach right angle sash lock with 3 4 19mm or 1 screw as shown Fig 9 2 12 7mm Fig 9...

Страница 17: ...irm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit from window Store parts WITH air conditioner Board thickness as required fo...

Страница 18: ...ils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before...

Страница 19: ...nch Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head locking screw for top angle side retainer 5 16 inch Long 2 ea 7 1 4ea 2ea 2 10 Foam insert 2 Window sash seal foam 1 A Window Mount...

Страница 20: ...tigh ten Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in window 1 Open window and mark center of window inner sill as shown Fig 11 2 Place cabinet in window with...

Страница 21: ...ise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Install support br...

Страница 22: ...gh the hole in the top leg of each window filler panel and into the window sash Fig 18A and Fig 18B Connect with one 3 4 or 1 2 long hex head screw 8 1 Trim sash seal to fit window width Insert into s...

Страница 23: ...In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1 After the unit is installed t...

Страница 24: ...d except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss...

Страница 25: ...versized to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL NOTE Caulking and installation of trim on interior wall may be done You can buy wood...

Страница 26: ...may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pinging or switching soun...

Страница 27: ...ctional Louvers Lever Air Direction The louvers will allow you to direct the air flow Left or Right throughout the room as needed Move the Levers from side to side until the desired Left Right directi...

Страница 28: ...kwise for higher cool settings Higher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher...

Страница 29: ...ROL OPERATING INSTRUCTIONS Auto Low Med High Follow Me Auto Cool Dry Fan Mode Fan Energy Saver Check Filter On Off Sleep Timer Ion TEMP TIMER Low Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On...

Страница 30: ...the remote control towards the unit and press the Follow Me button T If the unit does not receive the Follow Me signal during any 7 minutes interval the unit will beep to indicate the Follow Me mode...

Страница 31: ...w Be sure to unplug the unit before cleaning to prevent shock or fire hazards Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary Trapped particl...

Страница 32: ...cted Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem...

Страница 33: ...stricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting to bring air past cooling coils...

Страница 34: ...gn and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the ser...

Отзывы: