2. Location selection
2. Location selection
2.1 Unit location selection can refer to
installation manual.
2.2 DO NOT install the unit in the following
locations:
•
Where oil drilling or fracking is taking place.
•
Coastal areas with high salt content in the air.
•
Areas with caustic gases in the air, such as near hot
springs.
•
Areas with power fluctuations, such as factories.
•
Enclosed spaces, such as cabinets.
•
Areas with strong electromagnetic waves.
•
Areas that store flammable materials or gas.
•
Rooms with high humidity, such as bathrooms or
laundry rooms.
•
If possible, DO NOT install the unit where it is ex-
posed to direct sunlight.
2.3 The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to
airtight rooms. Be sure to keep the unit
unobstructed in at least two of the three
directions (M, N, P)
M
N
P
30
cm
/ 1
1.8
” f
rom
ba
ck
wa
ll
60 cm / 2
3.6” on rig
ht
60 cm / 23.6” abov
e
30 cm / 11
.8” on left
200
cm
/ 7
8”
in f
ron
t
2.4 Rows of series installation
The relations between H, A and L are as follows.
L
A
L
≤
H
L
≤
1/2H
25 cm / 9.8” or
more
1/2H < L
≤
H
30 cm / 11.8” or
more
L > H
Can not be installed
L
H
300
cm
/ 11
8”
or
mo
re
A
60
cm
/ 2
3.6
”
or
more
150
cm
/ 59”
o
r m
ore
25 cm / 9.8”
or more
25 cm / 9.8”
or more
DO NOT install the rows of series like following figure.
2.5. If the location is exposed to strong
winds (for example: near a seaside), the unit
must be placed against the wall to shelter it
from the wind. If necessary, use an awning.
Strong wind
DO NOT
Содержание MUEU-18HRFNX-QRD0W
Страница 1: ...LIGHT COMMERCIAL INVERTER SERIES SM_LC GA _R410A_R32_3D INV_EU_NA_1811 SERVICE MANUAL...
Страница 2: ......
Страница 5: ......
Страница 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Страница 12: ...Contents 1 Model Reference 2 2 External Appearance 3 Model Reference...
Страница 14: ...Model Reference 3 2 External Appearance 2 1 Indoor Unit Compact Four way Cassette A6 Duct Floor Ceiling...
Страница 15: ...Model Reference 4 2 2 Outdoor Unit Outdoor Unit...
Страница 19: ...IDU Compact Cassette 4 2 Dimensional Drawings...
Страница 21: ...IDU Compact Cassette 6 4 Service Place...
Страница 24: ...IDU Compact Cassette 9 Heating airflow velocity distributions Heating temperature distributions...
Страница 26: ...IDU Compact Cassette 11 Heating airflow velocity distributions Heating temperature distributions...
Страница 44: ...Outdoor Unit 3 Panel Plate B30...
Страница 45: ...Outdoor Unit 4 Panel Plate BA30...
Страница 46: ...Outdoor Unit 5 Panel Plate CA30...
Страница 47: ...Outdoor Unit 6 Panel Plate D30...
Страница 48: ...Outdoor Unit 7 Panel Plate E30...
Страница 49: ...Outdoor Unit 8 Panel Plate 590...
Страница 50: ...Outdoor Unit 9 2 Service Place...
Страница 62: ...Outdoor unit printed circuit board diagram 17122000002718...