35
9.1 Indoor Unit Error Display
Display
LED STATUS
E0
EEPROM parameter error
E1
Indoor / outdoor units communication protection
E2
Zero-crossing signal error
E3
Indoor fan speed out of control
E5
Open or short circuit of outdoor temperature sensors
E6
Open or short circuit of indoor temperature sensors
E7
Outdoor fan speed out of control
E8
Reset error of Auto Clean filters
P0
IGBT over-strong current protection
P1
Over voltage or too low voltage protection
P2
Temperature protection of compressor top.
P4
Inverter compressor drive error
Note: E4 & P3: Reserved function