41
9.3.8 IPM malfunction or IGBT over-strong current protection diagnosis and solution(P0)
Error Code
P0
Malfunction decision
conditions
When the voltage signal that IPM send to compressor drive chip
is abnormal, the display LED will show
“
P0
”
and AC will turn off.
Supposed causes
●
Wiring mistake
●
IPM malfunction
●
Outdoor fan ass
’
y faulty
●
Compressor malfunction
●
Outdoor PCB faulty
Trouble shooting: