12
6 Installation Details
6.1 Wrench torque sheet for
installation
Outside diameter
Torque
Additional tightening
torque
Ф
6.35mm
1/4in
1500N.cm(153kgf.cm)
1600N.cm(163kgf.cm)
Ф
9.52mm
3/8in
2500N.cm(255kgf.cm)
2600N.cm(265kgf.cm)
Ф
12.7mm
1/2in
3500N.cm(357kgf.cm)
3600N.cm(367kgf.cm)
Ф
15.9mm
5/8in
4500N.cm(459kgf.cm)
4700N.cm(479kgf.cm)
Ф
19mm
3/4in
6500N.cm(663kgf.cm)
6700N.cm(683kgf.cm)
6.2 Connecting the cables
The power cord should be selected according
to the following specifications sheet.
Appliance Amps
AWG Wire Size
10
18
13
16
18
14
25
12
30
10
The cable size and the current of the fuse or
switch are determined by the maximum
current indicated on the nameplate which
located on the side panel of the unit. Please
refer to the nameplate before selecting the
cable, fuse and switch.
6.3 Pipe length and the elevation
Models
Pipe size
Gas
Liquid
MSMBB-12CRDN1-MP0W
+
MOB1-12CDN1-M
P0W
3/8in
(
Ф
9.52mm)
1/4in
(
Ф
6.35mm)
MSMBC-18CRDN1-MP0W+MOC-18CDN1-M P0W
1/2in
(
Ф
12.7mm)
1/4in
(
Ф
6.35mm)
MSMBD-22CRDN1-MP5W+MOF1-22CDN1-
M P5W
5/8in
(
Ф
15.9mm)
3/8in
(
Ф
9.52mm)
Models
Standa
rd
length
Max.
Elevation
Max.
Length
A
Additional
refrigerant
MSMBB-12CRDN1-MP0W
+
MOB1-12CDN1-M
P0W
7.5m
(24.6ft)
10m
(32.8ft)
25m
(82.0ft)
15g/m
(0.16oz/ft)
MSMBC-18CRDN1-MP0W+
MOC-18CDN1-M P0W
7.5m
(24.6ft)
20m
(65.6ft)
30m
(98.4ft)
15g/m
(0.16oz/ft)
MSMBD-22CRDN1-MP5
W+MOF1-22CDN1-M
P5W
7.5m
(24.6ft)
20m
(65.6ft)
30m
(98.4ft)
30g/m
(0.32oz/ft)
Содержание MSMBB-12CRDN1-MP0W
Страница 7: ...5 2 2 Part names of Indoor Outdoor units ...
Страница 9: ...7 For MSMBB 12CRDN1 MP0W For MSMBC 18CRDN1 MP0W For MSMBD 22CRDN1 MP5W ...
Страница 13: ...11 MOF1 22CDN1 MP5W ...
Страница 25: ...23 ...
Страница 32: ...30 MOF1 22CDN1 MP5W ...
Страница 36: ...34 9 2 3 Zero crossing detection error diagnosis and solution E2 ...
Страница 39: ...37 supply or 50V 115V power supply the PCB must has problems and need to be replaced ...
Страница 45: ...43 P W N U ...
Страница 46: ...44 N V N W ...