Content
- 2 -
10.8
Heating mode ............................................................................................................................. 37
10.9
Defrosting mode(available for heating mode) ............................................................................ 38
10.10
Auto mode .................................................................................................................................. 39
10.11
Force cooling function ................................................................................................................ 39
10.12
Sleep mode................................................................................................................................. 40
10.13
Auto restart function.................................................................................................................... 41
11.
Model and Parameters...............................................................................................42
12.
Troubleshooting .........................................................................................................43
12.1
Display board.............................................................................................................................. 43
12.2
Troubleshooting .......................................................................................................................... 44
12.3
Diagnostic chart .......................................................................................................................... 45
12.4
Resetting phenomenon often occurs during operation. ............................................................. 46
12.5
Operation lamp flashes and Timer lamp off. .............................................................................. 46
12.6
Operation lamp flashes and Timer lamp on. .............................................................................. 46
12.7
Operation lamp off and Timer lamp flashes................................................................................ 47
12.8
Operation lamp on and Timer lamp flashes ............................................................................... 47
12.9
Operation lamp flashes, Timer lamp flashes . ............................................................................ 47
13.
Characteristic of temperature sensor ......................................................................48
Содержание MSG-24CR
Страница 1: ...MSG 24CR MSG 24HR MSG 30CR MSG 30HR MSG 36CR MSG 36HR...
Страница 2: ......
Страница 16: ...Service manual 12 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Страница 18: ...Service manual 14 However excludes the initial pull down stage...
Страница 19: ...Service manual 15 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Страница 20: ...Service manual 16 7 2 Wiring diagram 7 2 1 Cooling mode MSG 24CR MSG 30CR...
Страница 21: ...Service manual 17 MSG 36CR...
Страница 22: ...Service manual 18 7 2 2 Heating mode MSG 24HR MSG 30HR A1 A2...
Страница 23: ...Service manual 19 MSG 36HR A1 A2...
Страница 24: ...Service manual 20 7 2 3 Cooling mode 3 Ph MSG 30CR 3ph...
Страница 25: ...Service manual 21 MSG 36CR 3ph...
Страница 26: ...Service manual 22 7 2 4 Heating mode 3 Ph MSG 30HR 3ph 1 7 3 4 5 6 2...
Страница 27: ...Service manual 23 MSG 36HR 3ph...