background image

  Page 7  

NOTICE

•  Do not use this device to turn the unit on or off.

• Always 

m

ake sure the RESET button is pushed in for correct operation.

•  The power supply cord 

m

ust be replaced if it fails to reset when either the TEST 

button is pushed, or it can not be reset. Please contact Custo

m

er Service.

NOTICE

The power supply cord with this 
air conditioner contains a current 
detection device designed to reduce 
the risk of fire.

In the event that the power supply 
cord is da

m

aged, it can not be 

repaired. It 

m

ust be replaced with a 

cord fro

m

 the 

m

anufacturer.

Grounding type wall receptacle

Do not, under any 
circumstances, cut, 
remove or bypass 
the grounding prong.

Power supply cord with 3-prong grounding 
plug and current detection device.

The power supply cord contains a current 
measuring device that detects damage to 
the power cord. Test your power supply 
cord as follows:

1.  Plug in the air conditioner.

2.  The power supply cord will have TWO 

buttons on the plug head. Press the 
TEST button. You will notice a click as 
the RESET button pops out.

3.  Press the RESET Button. You will 

notice a click as the button engages.

4.  The power supply cord is now 

supplying electricity to the unit. (On 
some products this is also indicated 
by a light on the plug head.)

RESET

TEST

Plug in &

press RESET

Operation of Current Device

Saf

ety

Pr
ecautions

Содержание MP12SVWBA3RCM

Страница 1: ...ore using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with...

Страница 2: ...e Center at 1 866 646 4332 This appliance is not intended for use by people including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have...

Страница 3: ...r smells or smoke coming from it A damaged product may cause fire and electric shock Ventilate room before operating the air conditioner if there is a gas leakage from another appliance Do not operate...

Страница 4: ...shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit...

Страница 5: ...ater is spilled on the unit turn off the unit and switch off the circuit breaker Isolate supply by taking the power plug out and contact customer service Do not use near gas stove or other gas burning...

Страница 6: ...ignition source for example an operating electric heater close to the appliance The appliance shall also be stored in a room without ignition sources Do not pierce or burn Be aware that the refrigera...

Страница 7: ...type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong Power supply cord with 3 prong grounding plug and current detection device The power supply cord contains a...

Страница 8: ...5 C 55 F 95 F Heat Pump for heat model 5 C 30 C 41 F 86 F Handle both sides Power plug storage Power cord storage Upper air filter behind the grille Inlet and outlet air hose Air inlet Drain Outlet dr...

Страница 9: ...t will illuminate depending on the selected setting Fan Button Controls the fan speed Press to control the fan speed in four steps LOW MID HIGH and AUTO The selected fan speed light except AUTO will i...

Страница 10: ...onnect the duct to a window TIMER Auto Start Stop Operation When the unit is on pressing the Timer button will initiate the Auto stop program The TIMER OFF indicator light illuminates Press the Up or...

Страница 11: ...The remote s display will show the actual temperature at its location as long as it is within the 26 feet of the air conditioner The remote control will send this signal to the air conditioner every...

Страница 12: ...ioning DO NOT cover the Intakes Outlets or Remote Signal Receptor of the unit as this could cause damage to the unit Scan this QR code to watch an installation video for your Midea Duo Portable Air Co...

Страница 13: ...liding Window Adapter Front Sliding Window Adapter Rear Sliding Window Adapter Air Divider Bolt Foam seal A adhesive Foam seal B adhesive Foam seal C Non adhesive Security bracket and 2 screws Drain h...

Страница 14: ...of the window slider Use the combination of panels that best fits your window opening 2 If the length of the window requires two or more window sliders use the bolt to fasten the window sliders once...

Страница 15: ...ose panel to brace against the window so the window slider panels do not lean inward Foam seal B Adhesive type shorter Foam seal A Adhesive type Window slider Window slider if required Window Kit Brac...

Страница 16: ...e fully assembled adapter should look like the image at the left 3 Insert the window slider assembly into the window track If the hose opening is covered by the window frame rotate the panel so the th...

Страница 17: ...t 6 If desired install the security bracket with 2 screws as shown 7 Attach the Sliding Window Adapter to the hose by lining up the circles on the adapter the hose Insert the window slider adapter int...

Страница 18: ...ain hose adaptor While operating in heat pump mode the unit will produce condensate that must be drained You must install the drain hose when operating in heat mode To install the drain hose remove th...

Страница 19: ...and prevent mold Turn off the unit and unplug it Clean the air filter according to the instructions in the previous section Reinstall the clean dry filter before storing Remove the batteries from the...

Страница 20: ...the set temperature Make sure all windows and doors are closed The room area could be too large doublecheck the cooling area Check the room for possible heat sources and remove them if possible The un...

Страница 21: ...SE INSULATION FOAM If you are experiencing condensation on the outer section of the hose during heating operation apply the included heat pump insulation foam to the outside of the hose Use the includ...

Страница 22: ...t your local dealer CAUTION Remote Control and App Instructions LOCATION OF THE REMOTE CONTROL Use the remote control within a distance of 26 ft 8m from the air conditioner pointing it towards the uni...

Страница 23: ...ure is 86 F 30 C Sets timer to turn unit on see How to Use Basic Functions for instructions SET Scrolls through operation functions as follows The selected symbol will flash on the display area press...

Страница 24: ...ry detection display If flashes Displays when LOCK feature is activated Lights up when remote sends signal to indoor unit Displays the current mode including TIMER ON display TIMER OFF display Display...

Страница 25: ...ress up or down button for multiple times to set the desired time to turn off the unit Point remote to unit and wait 1 sec the TIMER ON will be activated Point remote to unit and wait 1 sec the TIMER...

Страница 26: ...at least a 5 megapixel camera 5 Due to unstable network connectivity requests may time out If this happens re run the network configuration 6 Due to unstable network connectivity commands may time ou...

Страница 27: ...ired to connect 3 Smart Air Conditioner Android QR code Apple QR code Scan to download app You can also go to Google Play or App Store and search for Midea Air DOWNLOAD AND INSTALL THE APP SYSTEM OVER...

Страница 28: ...mail NOTICE Make sure your smartphone is able to connect to the wireless network which will be used Make sure also that the device is not connecting to other networks in range CREATE YOUR ACCOUNT 1 Pr...

Страница 29: ...age 29 Remote Control and App Instructions ADDITIONAL APP AND SMART HOME FUNCTIONS For additional instructions regarding the features of the app and Smart Home skill capabilities scan the QR code belo...

Страница 30: ...oes not cover the following 1 Failure caused by damage to the unit while in your possesion other than damage caused by defect or malfunction by its improper installation or by unreasonable use of the...

Страница 31: ......

Страница 32: ...ers the body it can cause severe internal burns and can lead to death in as little as 2 hours Always completely secure the battery compartment If the battery compartment does not close securely stop u...

Отзывы: