45
then turn off automatically when reaching the setting “off” time.
8.4.7.5 Timer off/on. The machine will turn off automatically when reaching the setting “off” time, and
then turn on automatically when reaching the setting “on” time.
8.4.7.6 The timer function will not change the AC current operation mode. Suppose AC is off now, it will
not start up firstly after setting the “timer off” function. And when reaching the setting time, the timer
LED will be off and the AC running mode has not been changed.
8.4.7.7 The setting time is relative time.
8.4.8 Sleep function mode
8.4.8.1 Operation time in sleep mode is 7 hours. After 7 hours running, the AC will quit this mode and
turn off.
8.4.8.2. Operation process in sleep mode is as follow:
After pressing ECONOMIC or SLEEP button on the controller, the machine will turn into sleep mode.
When cooling, the setting temperature rises 1
℃
(be lower th
setting temperature stops rising and the indoor fan is fixed as low speed.
For heat pump models, when they are in heating, the setting temperature decreases 1
℃
(be higher
than 17
℃
) every one hour, 2 hours later the
the indoor fan is fixed
as low speed.(Anti-cold wind function has the priority)
8.4.8.3 Timer setting is available
8.4.8.4 When user uses timer off function in sleep mode (or sleep function in timer off mode), if the
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing
is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes
and turn to drying mode with 24
℃
setting tem p.
If AC is off before power off and AC is required to start up now, the compressor will have 20 seconds
Содержание MOA-11HN1-QB8
Страница 1: ...LUNA ON OFF SERIES Service Manual 2014 9ASEU B1 1401...
Страница 16: ...14 MS9A 12HRN1 QC7G...
Страница 17: ...15 MS9A 18HRN1 QC5...
Страница 18: ...16 MS9A 24HRN1 QB8W...
Страница 20: ...18 MOC 17HN1 QC0...
Страница 21: ...19 MOC 18HN1 QC0 MOF3 18HN1 QC5...
Страница 22: ...20 MOP 24HN1 QB8W...
Страница 23: ...21 MOF1 24HN1 QB8W...