Caution

  Do not use the unit until the qualified technician instructs you that it is safe 

to do so.

  Do not place appliances that produce naked flames in the path of the airflow 

from the unit. The airflow from the unit may increase the rate of combustion, 
which may cause a fire and cause serious injury or death. Alternatively, the 
airflow  may  cause  incomplete  combustion  which  can  lead  to  reduced 
oxygen concentration in the room, which can cause serious injury or death.

  Only use the air conditioner for its intended purpose. This unit should not be 

used to provide refrigeration or cooling for food, plants, animals, machinery, 
equipment or art.

  Do not insert your fingers or other objects into the unit’s air inlet or air outlet 

to avoid injury or damage to the equipment.

  The  fins  on  the  unit’s  heat  exchanger  are  sharp  and  can  cause  injury  if 

touched. To prevent injury, when the unit is being serviced, gloves should 
be worn or the heat exchanger should be covered.

  Do not place items which might be damaged by moisture under the unit. When 

the humidity is greater than 80% or if the drain pipe is blocked or the air filter is 
dirty, water could drip from the unit and damage objects placed under the unit.

Figure 9.1

Air Intake

Air Filter

Grounding Screw 

(in the control box)

Lock Buckle (for closing 

the Air Grille)

  Ensure that the drain pipe functions properly. If the drain pipe is blocked by 

dirt or dust, water leaks may occur when the unit is running in cooling mode. 
If this happens, turn the unit off and contact your supplier or service engineer.

•     Do not touch the internal parts of the controller. Do not remove the 

front 

 panel. Some internal parts may cause injury or be damaged.

  Ensure  that  children,  plants  and  animals  are  not  directly  exposed  to  the 

airflow from the unit.

  When fumigating a room with insecticide or other chemicals, cover the unit 

well and do not run it. Failure to observe this caution could lead to chemicals 
getting  deposited  inside  the  unit  and  later  emitted  from  the  unit  when  it 
running, endangering the health of any room occupants.

  Do  not  dispose  of  this  product  as  unsorted waste.  It  must  be  separately 

collected and  processed.  Ensure  that  all applicable  legislation  regarding 
the disposal of refrigerant, oil and other materials is adhered to. Contact your 
local waste disposal authority for information about disposal procedures.

  To avoid damaging the remote controller, exercise caution when using it and 

replacing its batteries. Do not place objects on top of it.

  Do not place appliances that have naked flames under or near the unit, as 

heat from the appliance can damage the unit.

  Do not place the unit’s remote controller in direct sunlight. Direct sunlight 

can damage the remote controller’s display.

  Do  not  use  strong  chemical  cleaners  to  clean  the  unit,  as  doing  so  can 

damage the unit’s display or other surfaces. If the unit is dirty or dusty, use 
a slightly damp cloth with very diluted and mild detergent to wipe the unit. 
Then, dry it with a dry cloth.

  Children shall not play with the appliance.

9. Part Names

The figure shown above is for reference only and may be slightly different from 
the actual product.

Air Outlet Louver (adjustable)
For in-situ adjustment to three-direction or two-direction,please contact the local 
dealer.

15

10. The Explain Of The Display Panel

The display panel has two types and the appearance of the two types are shown in Figure 10.1 and Figure 10.2.

Figure 10.1

Digital

display

Timer

indicator

ALARM

Anti-cold air /

defrosting indicator

Operation

indicator

Infrared signal

receiving window

Do not dispose of this product as unsorted

waste. It must be separately collected

and processed. Ensure that all

applicable legislation regarding the

disposal of refrigerant, oil and other

materials is adhered to. Contact your 

local waste disposal authority for

information about disposal procedures.

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the 

appliance.

This appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge if they have been given supervision or instruction 

concerning use of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without supervision.

Содержание MI2-100Q4DHN1

Страница 1: ...ion DC VRF indoor unit Installation and Operation Manual Original instructions Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Страница 2: ......

Страница 3: ...s and wires Improper wiring and installation may cause a fire Make sure the power cord communication and controller wiring are straight and level when you are working on the connections and the cover on the electric box is tight If the electric box is not closed properly it may lead to electric shock fire or overheating of electrical components If the refrigerant leaks during installation open the...

Страница 4: ...ontent the mechanical parts will experience accelerated ageing which will severely compromise the service life of the unit 5 Where there are major voltage fluctuations Operating the unit using a power supply system that has large voltage fluctuations will reduce the service life of the electronic components and cause the unit s controller system to malfunction 6 Where there is a risk of leakage of...

Страница 5: ...39 mm inner diameter 32 mm The inner diameter is based on the diameter of the copper and PVC pipes The thickness of the pipe casing is 10 mm or more Increase the thickness of the casing 20 mm or thicker when the temperature exceeds 30 C or the humidity exceeds RH80 To purchase based on actual project requirements Use to connect indoor refrigerant piping Use to discharge condensed water from the in...

Страница 6: ...ections for the installation site See Figure 2 3 for the schematic on the direction of airflow If part of the air vent must be blocked you may insert an air baffle at the vent of the unit body to block the air flow See Figure 2 4 2 Choosing an Installation Site Figure 2 1 Panel Ceiling 910 mm ceiling hole position Air inlet Air outlet Air outlet Floor Connect to water piping outlet Figure 2 2 Conn...

Страница 7: ...or mounting and drill four Φ12mm X 50 55 mm holes Then embed and set up the expansion hook anchors purchased accessory 4 in these holes See Figure 3 2 During the installation of the hooks purchased accessory 5 make sure that the concave portion of the hanger corresponds to that of the expansion hook anchors Determine the appropriate hook length for installation based on the ceiling s height Remove...

Страница 8: ... Buffers Dimensions of unit ϕ75 fresh air vent Refrigerant piping vent liquid side C Refrigerant piping vent gas side D ϕ32 outer diameter of water discharge pipe Figure 3 10 Figure 3 11 Mounting hooks Master air conditioner Ceiling Panel Hex nut to adjust level All the figures in this manual are for illustration purposes only The actual air conditioner you purchased may not have the same appearan...

Страница 9: ...ective casing to wrap the connection terminals and use a reliable fixture to secure and strengthen the safety isolation of the terminals 4 Adjust the four panel hook screws see Figure 3 15 c to keep the panel level and lift it evenly up to the ceiling 5 Adjust the panel slightly in the d direction see Figure 3 15 d so that the centre of the panel aligns with the centre of the opening of the ceilin...

Страница 10: ... for the schematic on the installation dimensions of the air ducts Figure 3 22 See Figure 3 23 for the schematic on the air duct installation Figure 3 23 If only one air duct is connected The air volume in the air duct for the 5 6 8 0 kW model is about 300 360 m3 h The air volume in the air duct for the 9 0 14 0 kW models is about 400 640 m3 h Length of the air duct should not exceed 2 m If two ai...

Страница 11: ...ssive torque will damage the socket cap and the cap will not be tight if you apply insufficient torque leading to leakages 4 5 Air Tightness Test Carry out the air tightness test on the system according to the instructions in the installation manual of the outdoor unit 4 7 Vacuum Create a vacuum in the system according to the instructions in the installation manual of the outdoor unit 4 8 Refriger...

Страница 12: ... plugged to prevent water from leaking 5 Water Discharge Piping Installation 5 1 Water Discharge Piping Installation for Indoor Unit 1 Use PVC pipes for the water discharge pipes outer diameter 37 39 mm inner diameter 32 mm Based on the actual installation circumstance users can purchase the appropriate piping length from sales agent or local after sales service centre or purchase directly from th...

Страница 13: ...connect the power cord firmly To prevent the cord from being pulled out by external force make sure it is fixed securely Figure 6 2 shows the power supply terminal of the indoor unit Refer to Tables 6 1 and 6 2 for the specifications of the power cord and communication wire A wiring capacity that is too small will cause the electrical wiring to become too hot and lead to accidents when the unit bu...

Страница 14: ...adding the build out resistor at P and Q open Indoor and outdoor units Communication wire Connecting the shielded layer of the shielded wire Connect the shielded end of the shielded wire to the electronic controller box sheet metal here Signalling line between outdoor units Outdoor unit P Q Figure 6 6 The X1 X2 D1 D2 ports on the sides of the main control board and the unidirectional communication...

Страница 15: ...unit in the system are not controlled by the centralized controller Caution The system can connect up to 64 indoor units address 0 63 at the same time Each indoor unit can only have one address DIP switch in the system The addresses of any two indoor units in the same system cannot be the same Units that have the same address may malfunction 0 1 definition of each dial code switch means 0 means 1 ...

Страница 16: ...ad to electric shocks or injuries caused by moving parts such as the unit s fan Ensure that the power supply is disconnected before any servicing or maintenance is carried out Do not touch the unit or its remote controller with wet hands as doing so can lead to electric shocks Do not allow children to play near this unit as doing so risks injury Do not insert your fingers or other objects into the...

Страница 17: ...igerant oil and other materials is adhered to Contact your local waste disposal authority for information about disposal procedures To avoid damaging the remote controller exercise caution when using it and replacing its batteries Do not place objects on top of it Do not place appliances that have naked flames under or near the unit as heat from the appliance can damage the unit Do not place the u...

Страница 18: ...an air filters inside indoor units Caution The unit performs stably in the temperature range given in above table If the indoor temperature is outside the unit s normal operating range it may stop running and display an error code 16 Cooling mode Heating mode 17 32 C DB 15 27 C DB Indoor temperature Indoor humidity a Condensation will form on the unit surface and water dripping out of the unit whe...

Страница 19: ...ell Clean the filter every two weeks when you use it regularly b If the air conditioner is positioned in a dusty place clean the filter often c Replace the filter if it is too dusty to clean the replaceable air filter is an optional fitting 1 Take out the air intake grille Push the grille switches simultaneously as indicated in Fig 13 1 Then pull down the air intake grille together with the air fi...

Страница 20: ...t will start after the intentional delay is complete Heating mode is running when the following panel lights are on operation and the DEF FAN LED indicator Cause the indoor unit activates protective measures because of the low outlet temperature Caution When the power switch is connected some energy will be consumed even if the unit is not running Disconnect the power to save energy A degree of di...

Страница 21: ...s air inlet or outlet is blocked A refrigerant leak has occurred Low heating effect Doors or windows are not completely closed Close doors and windows Arrange for a professional technician to check the following A refrigerant leak has occurred 15 2 Unit troubleshooting A power cut has occurred the power to the premises has been cut off Air flows normally but doesn t cool The unit starts or stops f...

Страница 22: ... button is pressed Check whether the MODE indicated on the display is AUTO Check whether the MODE indicated on the display is DRY A power cut has occurred the power to the premises has been cut off Check whether the timer operation has come to an end when TIMER OFF is indicated on the display Check whether the timer operation has come to an end when TIMER ON is indicated on the display Check wheth...

Страница 23: ...oil error Line loosened or broken The electronic expansion valve in stuck Outdoor unit error Water level float stuck Water level switch not connected properly Damaged main PCB Drain pump has malfunctioned 6 E 7 E b E error M O R P E E d E r o r r e t i n u r o o d t u O E E r o r r e l e v e l r e t a W FE Indoor unit has not been assigned an address Communication error between indoor and outdoor ...

Страница 24: ...16126000002969 V G ...

Страница 25: ...改前后核对和检查 B版本升级到C版本 更新整本说明书 C版本升级到D版本 P12添加线径说明 D版本升级到E版本 P12页删除图6 10 X1 X2接地 P12页6 3所有屏蔽线接地要求转移到6 3 1 E版本升级到F版本 P11表6 3 Cable for fixed wiring中的 and 为 to 图号升级 P16室内机制热温度增加下限 技术要求 双胶纸80克 黑白印刷 A4 V F V G 更改材质为80g 其余不变 ...

Отзывы: