background image

MCAC-TSM-2008-02 

Contents 

Contents 

 

Part 1 General Information ........................................................................2

 

Part 2 Outdoor units ...................................................................................7

 

Part 3 Installation......................................................................................63

 

Part 4 Controller .......................................................................................79

 

 

Содержание MGC-F05W/N1

Страница 1: ...MCAC TSM 2008 02 Contents Contents i Part 1 General Information 2 Part 2 Outdoor units 7 Part 3 Installation 63 Part 4 Controller 79...

Страница 2: ......

Страница 3: ...tary Chiller is air cooled chiller and heat pump system the chiller itself built in with water pump expansion tank plate heat exchanger it is very simple for installer to install such kind of system P...

Страница 4: ...General Information MCAC TSM 2008 02 2 General Information Part 1 General Information 1 Model Names of Outdoor Units 3 2 External Appearance 4 3 Nomenclature 5 4 Features 6...

Страница 5: ...Power Supply V ph Hz MGC F05W N1 R410A 5 0kW 220 240 1 50 MGC F07W N1 R410A 7 2kW 220 240 1 50 MGC F09W N1 R410A 9 0kW 220 240 1 50 MGC F10W N1 R410A 10 5kW 220 240 1 50 MGC F10W SN1 R410A 10 5kW 380...

Страница 6: ...External Appearance MCAC TSM 2008 02 4 General Information 2 External Appearance MGC F05W N1 MGC F07W N1 MGC F09W N1 MGC F10W S N1 MGC F12W SN1 MGC F14W SN1 MGC F16W SN1...

Страница 7: ...02 Nomenclature General Information 5 3 Nomenclature MGC F 14 W S N1 Refrigerant N1 R410A Power Supply S 380 415V 50Hz 3ph 220 240V 50Hz 1ph Outdoor Unit Capacity 14kW F Fixed Speed Type Midea Mini Un...

Страница 8: ...r pressure gauge inspect water pressure all the time 5 Flexible control built in with controller inside the chiller and can be controlled in the room by remote control keyboard 6 Built in with voltage...

Страница 9: ...utdoor units 1 Specification 8 2 Dimensions unit mm 12 3 Service Space unit mm 15 4 Piping Diagram 16 5 Wiring Diagrams 17 6 Electric Characteristics 20 7 Capacity Tables 21 8 Operation Limits 37 9 So...

Страница 10: ...pper tube Inner grooved copper tube Coil length height width mm 893 880 893 880 Outdoor coil Number of circuits 4 7 Type RS15 6 3 WILO RS15 6 3 WILO Input H M L W 93 67 46 93 67 46 Water pump Outdoor...

Страница 11: ...height width mm 635 1220 66 635 1220 66 Outdoor coil Number of circuits 6 6 Type RL25 8 5 RL25 8 5 Input H M L W 210 175 120 210 175 120 Water pump Outdoor air flow m 3 h 6450 4250 6500 4300 Throttle...

Страница 12: ...ngth height width mm 807 1188 38 1 945 1188 38 1 Outdoor coil Number of circuits 7 7 Type RL25 8 5 RL25 8 5 Input H M L W 210 175 120 210 175 120 Water pump Outdoor air flow m 3 h 6465 4270 6470 4280...

Страница 13: ...h height width mm 718 1220 66 937 1188 57 15 Outdoor coil Number of circuits 12 14 Type RL25 8 5 RL25 8 5 Input H M L W 210 175 120 210 175 120 Water pump Outdoor air flow m3 h 6500 4300 6550 4483 Thr...

Страница 14: ...Specification MCAC TSM 2008 02 12 Installation 2 Dimensions unit mm 2 1 MGC F05W N1 MGC F07W N1...

Страница 15: ...MCAC TSM 2008 02 Outdoor units Outdoor units 13 2 2 MGC F09W N1 MGC F10W N1 MGC F10W SN1...

Страница 16: ...Specification MCAC TSM 2008 02 14 Installation 2 3 MGC F12W SN1 MGC F14W SN1 MGC F16W SN1...

Страница 17: ...n A B C D E MGC F05W N1 990 966 354 624 366 MGC F07W N1 990 966 354 624 366 MGC F09W N1 940 1245 360 600 376 MGC F10W N1 940 1245 360 600 376 MGC F10W SN1 940 1245 360 600 376 MGC F12W SN1 1070 1249 4...

Страница 18: ...o Name No Name 1 Compressor 6 Capillary 11 Water differential pressure switch 2 High pressure switch 7 Liquid receiver 12 Accumulator 3 4 way valve 8 Plate heat exchanger 13 Low pressure switch 4 Cond...

Страница 19: ...MCAC TSM 2008 02 Outdoor units Outdoor units 17 5 Wiring Diagrams 5 1 MGC F05W N1 MGC F07W N1...

Страница 20: ...Specification MCAC TSM 2008 02 18 Installation 5 2 MGC F09W N1 MGC F10W N1...

Страница 21: ...MCAC TSM 2008 02 Outdoor units Outdoor units 19 5 3 MGC F10W SN1 MGC F12W SN1 MGC F14W SN1 MGC F16W SN1...

Страница 22: ...1 2 0 8 2 MGC F10W N1 50Hz 220 240V 1ph 198V 254V 24 5 32 35 123 19 5 0 1 2 0 8 2 MGC F10W SN1 50Hz 380 415V 3ph 342V 440V 9 2 10 5 20 64 7 3 0 1 2 0 8 2 MGC F12W SN1 50Hz 380 415V 3ph 342V 440V 12 1...

Страница 23: ...Pa 1 8 1 8 1 8 1 9 1 9 1 9 Pat 2 1 2 1 2 1 2 2 2 2 2 2 Qev 0 83 0 84 0 86 0 88 0 89 0 91 35 0 Pev 18 5 19 8 21 0 22 5 24 0 25 5 Pf 4 6 4 7 4 9 5 0 5 1 5 2 Pa 1 9 1 9 1 9 2 0 2 0 2 0 Pat 2 2 2 2 2 2 2...

Страница 24: ...2 7 2 7 2 7 Pat 2 9 2 9 2 9 3 0 3 0 3 0 Qev 1 20 1 22 1 24 1 26 1 27 1 29 35 0 Pev 32 5 33 8 35 0 36 5 38 0 39 5 Pf 6 8 6 9 7 1 7 2 7 3 7 4 Pa 2 7 2 7 2 7 2 8 2 8 2 8 Pat 3 0 3 0 3 0 3 1 3 1 3 1 Qev...

Страница 25: ...3 3 3 Pat 3 4 3 4 3 5 3 6 3 6 3 6 Qev 1 3 1 3 1 4 1 4 1 5 1 5 35 Pev 28 0 30 4 33 9 35 0 38 0 420 Pf 7 0 7 3 7 5 7 7 8 0 8 3 Pa 3 4 3 4 3 5 3 6 3 6 3 6 Pat 3 7 3 7 3 8 3 9 3 9 3 9 Qev 1 2 1 3 1 3 1 4...

Страница 26: ...3 4 3 4 3 5 3 5 Pat 3 8 3 8 3 9 3 9 4 0 4 0 Qev 1 7 1 7 1 8 1 9 1 9 2 0 35 Pev 27 0 27 5 30 0 32 0 32 4 34 0 Pf 9 4 9 7 10 0 10 3 10 6 11 0 Pa 3 6 3 6 3 7 3 7 3 8 3 8 Pat 4 1 4 1 4 2 4 2 4 3 4 3 Qev...

Страница 27: ...3 3 4 3 4 3 5 3 5 Pat 3 8 3 8 3 9 3 9 4 0 4 0 Qev 1 7 1 7 1 8 1 9 1 9 2 0 35 Pev 27 0 27 5 30 0 32 0 32 4 34 0 Pf 9 4 9 7 10 0 10 3 10 6 11 0 Pa 3 6 3 6 3 7 3 7 3 8 3 8 Pat 4 1 4 1 4 2 4 2 4 3 4 3 Qev...

Страница 28: ...4 3 4 3 4 3 Pat 4 8 4 8 4 8 4 9 4 9 4 9 Qev 2 0 2 0 2 1 2 1 2 2 2 2 35 Pev 21 1 23 2 25 4 27 0 28 8 30 0 Pf 10 9 11 2 11 5 11 8 12 1 12 4 Pa 4 5 4 5 4 5 4 6 4 6 4 6 Pat 5 1 5 1 5 1 5 2 5 2 5 2 Qev 1 9...

Страница 29: ...6 4 7 4 7 4 7 Pat 5 1 5 1 5 1 5 2 5 2 5 2 Qev 2 3 2 4 2 4 2 5 2 5 2 5 35 Pev 24 0 25 6 26 0 27 6 28 1 28 4 Pf 12 5 12 8 13 1 13 4 13 7 14 0 Pa 5 1 5 1 5 1 5 2 5 2 5 2 Pat 5 6 5 6 5 6 5 7 5 7 5 7 Qev...

Страница 30: ...0 6 1 6 1 6 1 Pat 6 5 6 5 6 5 6 6 6 6 6 6 Qev 2 6 2 6 2 7 2 7 2 8 2 8 35 Pev 28 2 29 5 31 0 32 3 34 0 35 1 Pf 14 2 14 5 14 8 15 1 15 4 15 7 Pa 5 5 5 5 5 5 5 6 5 6 5 6 Pat 6 0 6 0 6 0 6 1 6 1 6 1 Qev...

Страница 31: ...1 7 1 9 Pat 1 7 1 8 2 2 2 Qc 0 96 0 95 0 95 0 93 7 Pc 23 9 23 4 23 22 9 Pt 6 1 6 1 6 6 Pa 1 4 1 5 1 7 1 9 Pat 1 7 1 8 2 2 2 Qc 1 05 1 05 1 03 1 03 10 Pc 27 8 27 5 27 1 27 Pt 6 5 6 5 6 5 6 4 Pa 1 4 1 6...

Страница 32: ...t 2 6 2 7 2 9 3 1 Qc 1 34 1 32 1 32 1 31 7 Pc 36 9 36 4 36 35 9 Pt 8 3 8 3 8 2 8 2 Pa 2 3 2 4 2 6 2 8 Pat 2 6 2 7 2 9 3 1 Qc 1 43 1 43 1 41 1 41 10 Pc 40 8 40 5 40 1 40 Pt 8 7 8 7 8 7 8 6 Pa 2 3 2 5 2...

Страница 33: ...t 3 3 3 5 3 8 4 1 Qc 1 6 1 6 1 6 1 6 7 Pc 48 5 48 2 47 8 47 4 Pt 9 5 9 5 9 5 9 4 Pa 3 1 3 3 3 6 3 9 Pat 3 4 3 6 3 9 4 2 Qc 1 7 1 7 1 7 1 7 10 Pc 56 8 56 2 55 7 55 3 Pt 10 2 10 2 10 2 10 1 Pa 3 2 3 4 3...

Страница 34: ...3 8 4 1 4 3 4 6 Qc 2 0 2 0 2 0 1 9 7 Pc 37 2 35 8 34 5 33 1 Pt 12 3 12 2 12 1 12 0 Pa 3 4 3 7 3 9 4 2 Pat 3 9 4 2 4 4 4 7 Qc 2 1 2 1 2 1 2 1 10 Pc 40 5 40 0 39 2 38 8 Pt 13 8 13 7 13 6 13 5 Pa 3 5 3...

Страница 35: ...t 3 8 4 1 4 3 4 6 Qc 2 0 2 0 2 0 1 9 7 Pc 37 2 35 8 34 5 33 1 Pt 12 3 12 2 12 1 12 0 Pa 3 4 3 7 3 9 4 2 Pat 3 9 4 2 4 4 4 7 Qc 2 1 2 1 2 1 2 1 10 Pc 40 5 40 0 39 2 38 8 Pt 13 8 13 7 13 6 13 5 Pa 3 5 3...

Страница 36: ...Pat 4 5 4 8 5 1 5 4 Qc 2 3 2 3 2 3 2 3 7 Pc 44 0 43 6 43 1 42 8 Pt 14 4 14 3 14 2 14 1 Pa 4 0 4 3 4 6 4 9 Pat 4 6 4 9 5 2 5 5 Qc 2 5 2 5 2 5 2 5 10 Pc 38 0 37 6 37 2 37 0 Pt 15 9 15 8 15 7 15 6 Pa 4 1...

Страница 37: ...t 4 6 5 0 5 5 6 0 Qc 2 8 2 8 2 8 2 8 7 Pc 31 2 31 1 31 0 31 0 Pt 17 6 17 5 17 4 17 4 Pa 17 6 17 5 17 4 17 4 Pat 17 6 17 5 17 4 17 4 Qc 3 1 3 1 3 1 3 1 10 Pc 36 4 36 2 36 0 35 9 Pt 19 8 19 7 19 6 19 4...

Страница 38: ...5 3 Pat 4 1 4 5 5 0 5 6 Qc 2 7 2 7 2 7 2 7 7 Pc 30 2 30 1 30 30 Pt 16 9 16 8 16 7 16 6 Pa 3 9 4 3 4 8 5 3 Pat 4 2 4 6 5 1 5 6 Qc 3 0 3 0 3 0 3 0 10 Pc 35 4 35 2 35 34 8 Pt 19 18 9 18 8 18 7 Pa 4 0 4...

Страница 39: ...MCAC TSM 2008 02 Outdoor units Outdoor units 37 8 Operation Limits...

Страница 40: ...to pipeline or keep power on at standby or off status and ensure that water is contained inside of unit 2 When ambient temperature lower 5 running cooling mode must be charged antifreeze Refer to uppe...

Страница 41: ...ts 39 9 Sound Level 1 0m Microphone Outdoor Unit Unit Number Model Noise level dB A 1 MGC F05W N1 55 2 MGC F07W N1 56 3 MGC F09W N1 58 49 4 MGC F10W N1 60 50 5 MGC F10W SN1 58 48 6 MGC F12W SN1 59 49...

Страница 42: ...Specification MCAC TSM 2008 02 40 Installation 10 Exploded View 10 1 MGC F05W N1...

Страница 43: ...ormer 1 28 2 Safety valve 1 5 6 Main control board ass y 1 29 Suction pipe ass y 1 5 7 Urgency switch 1 29 1 Pressure controller 1 5 8 Filter board ass y 1 30 Connecting pipe ass y 1 5 9 Compressor ca...

Страница 44: ...Specification MCAC TSM 2008 02 42 Installation 10 2 MGC F07W N1...

Страница 45: ...Main control board ass y 1 28 2 Safety valve 1 5 7 Urgency switch 1 29 Suction pipe ass y 1 5 8 Filter board ass y 1 29 1 Pressure controller 1 5 9 Compressor capacitor 1 30 Connecting pipe ass y 1 6...

Страница 46: ...Specification MCAC TSM 2008 02 44 Installation 10 3 MGC F09W N1 MGC F10W N1...

Страница 47: ...2 Electronic control box subassembly 1 31 Discharge pipe subassembly 1 12 1 Motor capacitor 2 31 1 Pressure controller 1 12 2 E part box 1 32 Suction pipe subassembly 1 12 3 Power filter plate subasse...

Страница 48: ...Specification MCAC TSM 2008 02 46 Installation 10 4 MGC F10W SN1...

Страница 49: ...31 Discharge pipe ass y 1 12 2 E part box 1 31 1 Pressure controller 1 12 3 Filter board ass y 1 32 Suction pipe ass y 1 12 4 Transformer 1 32 1 Pressure controller 1 12 5 AC contactor 1 33 Compresso...

Страница 50: ...Specification MCAC TSM 2008 02 48 Installation 10 5 MGC F12W SN1 MGC F16W SN1...

Страница 51: ...rd ass y 1 27 6 Pipe joint 3 8 7 AC contactor 1 27 7 Pipe joint 2 9 Connecting pipe ass y 1 27 7 Rubber gasket 2 9 1 Copper nut 2 28 Suction pipe ass y 1 10 Top cover ass y 1 28 1 Pressure controller...

Страница 52: ...Specification MCAC TSM 2008 02 50 Installation 10 6 MGC F14W SN1...

Страница 53: ...1 27 1 Make up water valve 1 8 9 Power supply blue wire 1 27 2 Check valve tie in 1 8 10 Gas protection signal wire 1 27 3 Safety valve 1 8 11 Liquid protection signal wire 1 27 4 Water inlet pipe tie...

Страница 54: ...prevention alarm manual reset Er61 Water outlet sensor T02 malfunction automatic reset Er62 Coil sensor T03 malfunction automatic reset Er60 Water return sensor T01 malfunction automatic reset Er20 W...

Страница 55: ...ient temperature is 10 43 3 heating the indoor temperature is 30 and the outdoor temperature is 15 24 Stop the operation and run it at the normal condition No Yes Judge 3 Whether the refrigerant charg...

Страница 56: ...hether the temperature of external and inlet water is low Yes Check the operation conditions 1 the temperature of inlet water cooling below 20 heating below 45 2 cooling the indoor temperature is 17 a...

Страница 57: ...alue A Capacity kW Compressor current value A 5 18 10 3N 18 7 18 12 25 9 32 14 25 10 1N 32 16 25 Values display indication Er41 Judge 1 Whether the phase sequence of the power line is wrong connected...

Страница 58: ...c heater start working when water outlet temperature T02 6 water pump and electric heater stop working Judge 2 Check whether the electric heater is well Supply the power No Yes Replace the electric he...

Страница 59: ...er delivery sensor T02 malfunction Judge 1 Whether the sensor falls off Insert it well Yes No Judge 2 Check the electrical connection whether the sensor connects well No Connects it well Yes Judge 3 W...

Страница 60: ...tion manual Coil sensor T03 malfunction Judge 1 Whether the sensor falls off Insert it well Yes No Judge 2 Check the electrical connection whether the sensor connects well No Connect it well Yes Judge...

Страница 61: ...Water return sensor T01 malfunction Judge 1 Whether the sensor falls off Insert it well Yes No Judge 2 Check the electrical connection whether the sensor connects well No Connects it well Yes Judge 3...

Страница 62: ...is close Close the differential pressure switch No Yes Judge 2 Check whether the pump is setting high No Setting the pump in high Yes Judge 3 Check whether the air is in water circuit Vent the air Ju...

Страница 63: ...Judge Whether the three connecting lines red blue and black are wrong connected Connect them well in right sequence Yes Refer to the instruction manual Remote keyboard communication error Values displ...

Страница 64: ...red by manual reset please do as follow on the control interface Press esc set in the main screen The label PAr will appear Scroll with UP and DOWN to find the FnC label Press set The label dEF will a...

Страница 65: ...its 63 Part 3 Installation 1 General Information 64 2 Description of Standard Unit 65 3 Installation of Outdoor Unit 66 4 Hydraulic Connection 68 5 Electrical Connection 71 6 Checking and Starting Up...

Страница 66: ...hildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person resp...

Страница 67: ...starting torque and automatic venting of impeller chamber Pump assembly Pump assembly with expansion tank safety valve auto water replenishing assembly pressure gauge and pump Condensing coil Made fr...

Страница 68: ...k or similar bearing in mind the weight distribution of the unit To lift the unit insert tubes long enough to allow positioning of the lifting slings and safety pins in the feet on the unit To avoid t...

Страница 69: ...nsion A B C D E MGC F05W N1 990 966 354 624 366 MGC F07W N1 990 966 354 624 366 MGC F09W N1 940 1245 360 600 376 MGC F10W N1 940 1245 360 600 376 MGC F10W SN1 940 1245 360 600 376 MGC F12W SN1 1070 12...

Страница 70: ...t or a differential pressure switch inlet outlet 5 Two thermometers inlet and outlet 6 An inlet filter as close as possible to the evaporator and positioned to allow easy access for routine maintenanc...

Страница 71: ...priate treatment systems For reference values see the table PH 6 8 Electrical conductivity less than 200 mV cm 25 C Chlorine ions less than 50 ppm Sulphuric acid ions less than 50 ppm Total iron less...

Страница 72: ...SN1 78 84 174 297 148 148 R5 4 G1 2 G1 2 MGC F16W SN1 78 84 174 297 148 148 R5 4 G1 2 G1 2 Important a The installation must be filled to a pressure of between 1 and 2 bars b It is recommended that t...

Страница 73: ...m with a suitable device to protect against short circuits and leakage to earth isolating the installation from other equipment Voltage must be within a tolerance of 10 of the rated power supply volta...

Страница 74: ...50Hz Auxiliary Connection All terminals referred to in the explanations below are to be found on the terminal board inside the electrical panel and described as installer terminals Remote start up an...

Страница 75: ...r 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 Circuit breaker fuse A 25 20 30 25 40 25 40 35 Power wiring mm 2 3 2 5 3 2 5 3 4 0 3 4 0 Ground wiring mm 2 2 5 2 5 4 0 4 0 Outdoor Indoor connect...

Страница 76: ...carried out correctly Voltage is within a tolerance of 10 of the rated voltage for the unit The unit is correctly earthed All electrical and hydraulic connections are tight and have been completed cor...

Страница 77: ...to signal that voltage is present 6 3 Activating and deactivating the unit Set the remote keyboard A6 if present to ON To ACTIVATE and DEACTIVATE the COOLING and HEATING functions use the ST542 contr...

Страница 78: ...g from the pressure probe thus enabling heat exchange to be increased and or decreased maintaining the condensing or evaporation temperature practically constant The fan functions independently of the...

Страница 79: ...itions there should be no need for the Technical Assistance Service to intervene to check the refrigerant gas However over time small leaks may develop at the joints leading to loss of refrigerant and...

Страница 80: ...periods After deactivating the chiller Make sure the remote switch SA 2 is in the Standby position or alternatively disconnect the unit from the power supply Make sure the remote keyboard if present...

Страница 81: ...MCAC TSM 2008 02 Running and Maintenance Installation 79 Part 4 Controller 1 Standard Controller 80...

Страница 82: ...ncreases a value Goes to the next label Manual defrost activation DOWN DOWN Decreases a value Goes to the previous label Local ON OFF Esc ape Output Without saving new settings Exit without saving new...

Страница 83: ...uts dO dO1 dO2 dO3 dO4 dO5 dO6 Dynamic Digital outputs CL HOUr dAtE yeaR Clock Yes AL Er00 Er99 Dynamic Alarms SP Value Set points set Yes Sr Value Real set point Hr CP01 CP02 PU01 PU02 Dynamic Runnin...

Страница 84: ...pending on the setting on the digital controller the unit will operate in cooling or in heating mode Procedure a Connect the cable to the appropriate terminals as shown or the wiring diagram b Fix the...

Страница 85: ...02 Standard Controller Controller 83 2 Select Operating Mode There are three different operating modes Standby mode StbY Heat mode Cooling mode Instructions are provided below on how to change the op...

Страница 86: ...Standard Controller MCAC TSM 2008 02 84 Controller 3 Select the Clock CL...

Страница 87: ...d Controller Controller 85 4 Modifying a parameter Instructions are provided below on how to change a machine parameter By way of example let s look at the CF configuration parameters folder parameter...

Страница 88: ...Standard Controller MCAC TSM 2008 02 86 Controller 5 Set the set point SP By way of example we will change the set point value in COOL mode by 12 0 degrees centigrade to12 5 degrees centigrade...

Страница 89: ...MCAC TSM 2008 02 Standard Controller Controller 87...

Страница 90: ...ar on the display Use the UP and DOWN keys to scroll the other labels until you find the Hr label Press the set key to view the first label which in this case is the running time for compressor 1 CP01...

Страница 91: ...g folder EUr Press esc set in the main screen The label PAr will appear Scroll with UP and DOWN to find the FnC label Press set The label dEF will appear Scroll with UP and DOWN to find the EUr label...

Страница 92: ...n error message will be shown alternating with the error alert and the main display The ALARM LED will be permanently on An error can be acknowledged by pressing any key once After pressing any key th...

Страница 93: ...conditions fall within the limits specified in the table of technical data Check that the compressor current input is less than the maximum indicated in the table of technical data In three phase mod...

Страница 94: ...Standard Controller MCAC TSM 2008 02 92 Controller...