background image

6

Table 5-3 (14/16KW) 

No.

Fault or protection type

Recovery mode

Error code

1

Communication error between IDU and ODU

Recoverable

E2

2

T3 or T4 temperature sensor error

Recoverable

E4

3

Input voltage protection

Recoverable

E5

4

DC fan protection

Recoverable

E6

5

EEPROM fault

Unrecoverable

E9

6

Wrong compressor parameters

Unrecoverable

E.9.

7

E6 fault occurs more than six times in an hour.

Unrecoverable

Eb

8

PFC error

Unrecoverable

EF

9

Refrigerant radiator temperature sensor error

Recoverable

EH

10

DC bus voltage protection

Recoverable

F1

11

Communication between the main control board and the inverter fails.

Recoverable

H0

12

M-Home mismatch (reserved)

Recoverable

HF

13

L (L0/L1) fault occurs three times in one hour.

Unrecoverable

H4

14

The fault is increased or reduced on the IDU.

Recoverable

H7

15

IPM protection

Recoverable

L0

16

DC bus low voltage protection

Recoverable

L1

17

DC bus high voltage protection

Recoverable

L2

18

MCE error

Recoverable

L4

19

Zero speed protection

Recoverable

L5

20

Compressor phase sequence error

Recoverable

L7

21

Protection for compressor speed change > 15Hz

Recoverable

L8

22

Protection for the difference between the set speed and the running speed 

of the compressor > 15Hz

Recoverable

L9

23

Radiator surface temperature protection

Recoverable

PL

24

System high pressure protection

Recoverable

P1

25

System low pressure protection

Recoverable

P2

26

Overcurrent protection

Recoverable

P3

27

T5 discharge temperature protection

Recoverable

P4

28

T3 outdoor condenser temperature protection

Recoverable

P5

29

Typhoon protection

Recoverable

P8

30

T2 IDU evaporator temperature protection

Recoverable

PE

31

Ambient temperature less than or equal to -5°C in cooling mode (ODU 

reports the fault)

Recoverable

EP

If the problem remains, please contact the distributor or Midea's air conditioner customer service center, and provide info about the 

product model and the  fault details.

Display Function Instruction:

1. When stand by, LED displaying the amount of indoor units online which communicate with outdoor units.

2. When operation, LED displaying frequency value of compressor.

3. When defrost, LED displaying “dF”.

Содержание MDV-V100W/DN1

Страница 1: ...g our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference Mini VRF C Series Owner s Manual MDV V80W DN1 C MDV V100W DN1 C MDV V120W DN1 C MDV V140W DN1 C MDV V160W DN1 C ...

Страница 2: ...gerant pipe connector NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail 16kW complying with IEC 61000 3 12 Fig 1 ...

Страница 3: ...s the button of the remote controller with a hard pointed object The remote controller may be damaged Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire It is not good for your health to expose your body to the air flow for a long time Do not insert fingers rods or other objects into...

Страница 4: ... effectiveness of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components shorten their service life spans because of overheated for a long time The temperature of refrigerant circuit will be high please kee...

Страница 5: ...outlet position and set the fan speed to High 4 OPERATION AND PERFORMANCE 4 1 Protection Equipment This Protection Equipment will enable the Air Conditioner to stop when the Air Conditioner is to be directed running compulsively When the Protection Equipment is activated the Operation Indicator still lights while the Air Conditioner is not running But the Check Indicatior Lights The protection equ...

Страница 6: ... board stop abnormally Recoverable EE 2 Communication error between indoor and outdoor unit Recoverable E2 3 Outdoor heat exchanger temperature sensor T3 error or outdoor ambient temperature sensor T4 error Recoverable E4 4 Input voltage protection Recoverable E5 5 DC fan protection Recoverable E6 6 Discharge pipe temperature sensor error Recoverable E7 7 EEPROM mismatch Unrecoverable E9 8 Compres...

Страница 7: ...h reserved Recoverable HF 15 L L0 L1 fault occurs three times in one hour Unrecoverable H4 16 The fault is increased or reduced on the IDU Recoverable H7 17 IPM protection Recoverable L0 18 DC bus low voltage protection Recoverable L1 19 DC bus high voltage protection Recoverable L2 20 MCE error Recoverable L4 21 Zero speed protection Recoverable L5 22 Compressor phase sequence error Recoverable L...

Страница 8: ...speed protection Recoverable L5 20 Compressor phase sequence error Recoverable L7 21 Protection for compressor speed change 15Hz Recoverable L8 22 Protection for the difference between the set speed and the running speed of the compressor 15Hz Recoverable L9 23 Radiator surface temperature protection Recoverable PL 24 System high pressure protection Recoverable P1 25 System low pressure protection...

Страница 9: ...shah sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing sound is heard ...

Страница 10: ...arge refrigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Find reasons and solution Low cooling effect Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack o...

Страница 11: ...apse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air conditioner operation will stop up to the set time The TIMER ON indicator goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and the app...

Страница 12: ......