background image

1

CONTENTS PAGE

IMPORTANT SAFETY INFORMATION ...........................................................1

PARTS NAMES ............................................................................................2

OPERATION RANGE .....................................................................................3

OPERATION AND PERFORMANCE ...............................................................3

MALFUNCTION CODE OF OUTDOOR UNIT ...................................................4

FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES .............7

TROUBLESHOOTING ...................................................................................7

1.  IMPORTANT SAFETY INFORMATION

To prevent injury to the user or other people and property 

damage, the following  instructions must be followed. Incorrect 

operation due to ignoring of instructions may cause harm or 

damage. 

The safty precautions listed here are divided into two categories. In 

either case, important safty information is listed which must be read 

carefully.

WARNING

Failure to observe a warning may result in damage. The 

appliance shall be installed in accordance with national 

wiring regulations.

CAUTION

Failure to observe a caution may result in injury or damage 

to the equipment.

WARNING

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concerning 

use of the appliance in a safe way and understand the 

hazards involved. 

Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children 

without supervision.(Only European)

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their  

safety.

Children should be supervised to ensure that they do not play 

with the appliance.

The partial units shall only be connected to an appliance suitable 

for the same refrigerant.

The units 8-16kW are partial unit air conditioners, complying 

with partial unit requirements of this International Standard, and 

must only be connected to other units that have been confirmed 

as complying to corresponding partial unit requirements of this 

International Standard.

Ask your dealer for installation of the air conditioner. 

Incomplete installation performed by yourself may result in a 

water leakage, electric shock, and fire. 

Ask your dealer for improvement, repair, and maintenance. 

Incomplete improvement, repair, and maintenance may result in 

a water leakage, electric shock, and fire. 

In order to avoid electric shock, fire or injury, or if you detect 

any abnormality such as smell of fire, turn off the power 

supply and call your dealer for instructions.

Never let the indoor unit or the remote controller get wet. 

It may cause an electric shock or a fire.

Never press the button of the remote controller with a hard, 

pointed object. 

The remote controller may be damaged. 

Never replace a fuse with that of wrong rated current or 

other wires when a fuse blows out. 

Use of wire or copper wire may cause the unit to break down 

or cause a fire. 

It is not good for your health to expose your body to the 

air flow for a long time.

Do not insert fingers, rods or other objects into the air 

inlet or outlet. 

When the fan is rotating at high speed, it will cause injury. 

Never use a flammable spray such as hair spray, 

lacqueror paint near the unit. 

It may cause a fire. 

Never touch the air outlet or the horizontal blades while 

the swing flap is in operation. 

Fingers may become caught or the unit may break down. 

Never put any objects into the air inlet or outlet. 

Objects touching the fan at high speed can be dangerous.

Never inspect or service the unit by yourself. 

Ask a qualified service person to perform this work. 

Do not dispose this product as unsorted 

municipal waste. Collection of such waste 

separately for special treatment is necessary.

Do not dispose of electrical appliances as unsorted municipal 

waste, use separate collection facilities.

Contact you local government for information regarding the 

connection systems available.

If electrical appliances are disposed of in landfills 

or dumps, hazardous substances can leak into the 

groundeater and get into the food chain, damaging your 

health and well-being.

To prevent refrigerant leak, contact your dealer. 

When the system is installed and runs in a small room, it is 

required to keep the concentration of the refrigerant, if by any 

chance coming out, below the limit. Otherwise, oxygen in the 

room may be affected, resulting in a serious accident. 

The refrigerant in the air conditioner is safe and normally 

does not leak. 

If the refrigerant leaks in the room, contact with a fire of a 

burner, a heater or a cooker may result in a harmful gas.

Turn off any combustible heating devices, ventilate the 

room, and contact the dealer where you purchased the 

unit. 

Do not use the air conditioner until a service person confirms 

that the portion where the refrigerant leaks is repaired. 

CAUTION

Do not use the air conditioner for other purposes. 

In order to avoid any quality deterioration, do not use the unit 

for cooling precision instruments, food, plants, animals or 

works of art. 

Before cleaning, be sure to stop the operation, turn the 

breaker off or pull out the supply cord. 

Otherwise, an electric shock and injury may result. 

In order to avoid electric shock or fire, make sure that an 

earth leak detector is installed.

Be sure the air conditioner is grounded. 

In order to avoid electric shock, make sure that the unit is 

grounded and that the earth wire is not connected to gas or 

water pipe, lightning conductor or telephone earth wire.

Содержание MDV-V100W/DN1

Страница 1: ...g our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference Mini VRF C Series Owner s Manual MDV V80W DN1 C MDV V100W DN1 C MDV V120W DN1 C MDV V140W DN1 C MDV V160W DN1 C ...

Страница 2: ...gerant pipe connector NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail 16kW complying with IEC 61000 3 12 Fig 1 ...

Страница 3: ...s the button of the remote controller with a hard pointed object The remote controller may be damaged Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire It is not good for your health to expose your body to the air flow for a long time Do not insert fingers rods or other objects into...

Страница 4: ... effectiveness of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components shorten their service life spans because of overheated for a long time The temperature of refrigerant circuit will be high please kee...

Страница 5: ...outlet position and set the fan speed to High 4 OPERATION AND PERFORMANCE 4 1 Protection Equipment This Protection Equipment will enable the Air Conditioner to stop when the Air Conditioner is to be directed running compulsively When the Protection Equipment is activated the Operation Indicator still lights while the Air Conditioner is not running But the Check Indicatior Lights The protection equ...

Страница 6: ... board stop abnormally Recoverable EE 2 Communication error between indoor and outdoor unit Recoverable E2 3 Outdoor heat exchanger temperature sensor T3 error or outdoor ambient temperature sensor T4 error Recoverable E4 4 Input voltage protection Recoverable E5 5 DC fan protection Recoverable E6 6 Discharge pipe temperature sensor error Recoverable E7 7 EEPROM mismatch Unrecoverable E9 8 Compres...

Страница 7: ...h reserved Recoverable HF 15 L L0 L1 fault occurs three times in one hour Unrecoverable H4 16 The fault is increased or reduced on the IDU Recoverable H7 17 IPM protection Recoverable L0 18 DC bus low voltage protection Recoverable L1 19 DC bus high voltage protection Recoverable L2 20 MCE error Recoverable L4 21 Zero speed protection Recoverable L5 22 Compressor phase sequence error Recoverable L...

Страница 8: ...speed protection Recoverable L5 20 Compressor phase sequence error Recoverable L7 21 Protection for compressor speed change 15Hz Recoverable L8 22 Protection for the difference between the set speed and the running speed of the compressor 15Hz Recoverable L9 23 Radiator surface temperature protection Recoverable PL 24 System high pressure protection Recoverable P1 25 System low pressure protection...

Страница 9: ...shah sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing sound is heard ...

Страница 10: ...arge refrigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Find reasons and solution Low cooling effect Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack o...

Страница 11: ...apse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air conditioner operation will stop up to the set time The TIMER ON indicator goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and the app...

Страница 12: ......