Please read this installation manual carefully before installation.
The air conditioner must be installed by qualified service person.
When installing the indoor unit , please follow this manual as strictly as possible.
Check the piping is accomplished perfectly before electrifying the unit.
This manual is subject to changes due to technological improvement without further notices.

Note: 

The installer  should  illustrate to users how to  correctly use and  maintain the  appliance  

 

,

           and remind the users carefully reading and keeping both installation manual and owner s

          Manual after the installation.

1

2

1

2

5

1

           Name

Indoor unit installation manual

Insulation pipe

Remote controller(including 
operation manual)

Alkaline dry batteries (Am4)

Screw M4 16(including flat 

*

spring gasket)

Installation pattern paper

Installation indicator

Fixing belt

Straight pipe

Elbow

Big gasket

Electric throttle part

Insulation for pipe connection part

For fixing the installation pattern paper 
and panel(only for 28,36 model)

Adjust ceiling hole and position of indoor
unit(only for 28,36model)

Adjust main unit position(only for 45,56,
71 model)

Fixing and tightening 

Drainage

Connect drain pipe and straight pipe 

Hang the indoor unit

,

Q ty

Shape

                         Usage

ACCESSORIES

Cautions on remote controller installation:

Don t  throw the remote controller or give it big impact.
The remote controller should be in the reception range, and the transmittal part should point
to the orientation of indoor unit receptor.
Before installation, operate the remote controller to determine its location in a reception range.
Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment. (It
is necessary to prevent image disturbances or noise interferences.)
Do not install the remote controller in a place exposed to direct sunlight or close to a heating 
source, such as a stove.
Note that the positive and negative poles are right positions when loading batteries.
 

8

2

2

10

1

1

1

This manual

Содержание MDV-D28Q1/BN2

Страница 1: ...Please read this manual carefully before operation and keep it in a safe place for future reference One Way Cassette Type Indoor Unit With Panel Installation Manual Model MDV D28Q1 BN2 MDV D36Q1 BN2 MDV D45Q1 BN2 MDV D56Q1 BN2 MDV D71Q1 BN2 ...

Страница 2: ...llation Iocation 3 Install indoor unit 4 Drain pipe 5 Electric wiring 6 Install the panel 7 Refrigerant pipe installation 8 C o n t r o l 9 Trouble shooting table 10 2 2 5 6 8 8 9 11 Install electric throttle part 11 CONTENTS ...

Страница 3: ...ttle part Insulation for pipe connection part For fixing the installation pattern paper and panel only for 28 36 model Adjust ceiling hole and position of indoor unit only for 28 36model Adjust main unit position only for 45 56 71 model Fixing and tightening Drainage Connect drain pipe and straight pipe Hang the indoor unit Q ty Shape Usage ACCESSORIES Cautions on remote controller installation Do...

Страница 4: ... above 245mm above Ceiling 100mm above 200mm above Air outlet side Air inlet side MDV D45 71Q1 BN2 MDV D28 36Q1 BN2 INSTALL SPACE 200mm above Hanging screw bolt distance 890 Hanging screw bolt distance screw bolt distance 1230 MDV D28 36Q1 BN2 MDV D45 71Q1 BN2 screw bolt distance 330 530 2 Please install with f10 hanging screw bolts 1 The size of the ceiling to be handled Do keep the ceiling flat ...

Страница 5: ...ust the gasket down side to 137mm over the ceiling for MDV D28 36Q1 BN2 type and for MDV D45 71Q1 BN2 type adjust that to 130mm 130mm Down Side of the ceiling Hanging Bolt Nut Up Side Gasket Up Side Installing Ear Gasket Down Side Nut Down Side Install the hanging bolt into U groove of the hanging tool Overhang the indoor unit and ensure it is level using a level gauge Fasten the upside nut Level ...

Страница 6: ...t into U grove of the hanging tool Overhang the indoor unit and ensure it is level using a level gauge Use the installation paper pattern to confirm the position between the body and the ceiling opening Please refer to the following figure to install Fix the pattern paper to the down side of indoor unit with panel fixing screw Adjust the size of ceiling hole according to pattern paper Pattern pape...

Страница 7: ...not slant downward Lead it upward to a height 340 mm maximum then downward lead it When the drainage is upward the upward drain pipe and elbow of the accessories must be adopted and the height is less than 500mm otherwise the drain pump water level switch malfunction will be caused Ù No more than VP16 VP25 2 140 1 500below 1 When adopting upward drain pipe out off VP16 pipe to do the piping 2 The ...

Страница 8: ...ause electric shock If the wiring capacity is not enough electric shock or fire may occur Be sure to Install Current Leakage Protection Switch Or electric shock may occur Power cord is to be selected according to national regulations Outdoor unit power cord should be selected and connected according to the outdoor unit installation manual Wiring should be away from high temperature components or t...

Страница 9: ...e machine Model Items Power Cord of the Indoor Unit Control Wire Diameter Ground Wire Single Wire Power Capacity Fuse Below 20m Twisted pair 2 core screened wire Twisted pair Below 50m Quantity Power Switch Power Cord Indoor Outdoor Unit Signal Wire Single Phase 220 240V 50Hz 2 2mm 2 6mm Notlongerthan1500m 2 2mm 2 f1 5mm 15A MDV D28 71Q4 N2 15A WIRING SPECIFICATIONS The indoor unit power source sh...

Страница 10: ... the Pipes Requirements are different when installing the outdoor unit please refer to outdoor unit installation manual for detailed information Three length 3m 5m 10m of pipes are available to purchase f19 Copper Pipe for Air Conditioner Pipe Material Size mm Gas side Liquid side Refrigerant Volume to Be Added Refrigerant volume to be added is calculated according to outdoor unit installation man...

Страница 11: ...r Purging Open Close the valves Leakage Test Heat Insulation Wrap to the foot of the piping Field Piping side Unit Body Attached Heat Insulation Material Use a vacuum pump to vacuum from the gas side refrigerant adding mouth of the outdoor unit Open Close the spools or the valves of outdoor unit with a f5mm hexagon spanner Test if there is any leakage on the connections of the piping with soap wat...

Страница 12: ... 5 0HP 11200W 4 0HP 9000W 3 2HP 8000W 3 0HP 7100W 2 5HP 5600W 2 0HP 4500W 1 5HP 3600W 1 2HP 2800W 1 0HP ENC1 TOGGLE SWITCH FOR SETTING ADDRESS 0 F show the address 0 F respectively that is 0 15 indoor unit together 16 units and the others follow the analogy If two addresses are the same in one system the abnormal operation will occur 0 1 F 2 3 E 4 D 5 C 6 B 7 A 8 9 0 1 F 2 3 E 4 D 5 C 6 B 7 A 8 9 ...

Страница 13: ...e alarm will disappear Run lamp Timer lamp Defrost lamp Alarm lamp Manual Switch TROUBLE SHOOTING INSTALL ELECTRIC THROTTLE PART Please refer to the following figures to install The installation size is as follows 266 165 215 7 5 Electric throttle part wires group Indoor unit input pipe Connection pipe copper nut joint Electric throttle part pipe joint Indoor unit input pipe joint Electric throttl...

Страница 14: ...6294aw ...