background image

owner

s manual

CAUTION

Before  you  clean  the  air  conditioner,  be  sure  the  power 
supply is off.

Check if the wiring is not broken off or disconnected.

Use  a  dry  cloth  to  wipe  the  indoor  unit  and  remote 
controller.

A  wet  cloth  may  be  used  to  clean  the  indoor  unit  if  it  is 
very dirty.

Never use a damp cloth on the remote controller.

Do not use a chemically-treted duster for wiping or leave 
such material on the unit for long.

it may damage or fade the surface of the unit.

Do not use benzine, thinner, polishing powder, or similar 
solvents for cleaning.

 

These may cause the plastic surface to crack or deform.

Cleaning the air filter

The  air  filter  can  prevent  the  dust  or  other  particulate  from 
going  inside.

 

In  case  of  blockage  of  the  filter,  the  working 

efficiency of the air conditioner may greatly decrease .
Therefore, the filter must be cleaned once two weeks during 
long time usage.

If the air conditioner is installed in a dust place, clean the air 
filter frequent.

If  the  accumulated  dust  is  too  heavy  to  be  cleaned,  please 
replace  the  filter  with  a  new  one(replaceable  air  filter  is  an 
optional fitting).

Open the air-in grill 

    Push the grill switches towards the middle simultaneously as
    indicated in 

Fig.6-1

. Then pull down the air-in grill. 

The  control  box  cables  ,which  are  originally  connected  with 
the main body electrical terminators must be pulled off before 
doing as indicated above.

1

2

3

4

Take out the air-in grill (together with the air filter shown in 

Fig.6-1

).

    Pull the air-in grill down at 45  and lift it up to take out the
    grill.

Dismantle the air filter.

Clean the air filter

    Vacuum cleaner or pure water may be used to clean the air
    filter.If the dust accumulation is too heavy , please use soft
    brush and mild  detergent to clean it and dry out in cool place.

The air-in side should face up when using vacuum cleaner.

(

See Fig. 6-3

)

The air-in side should face down when using water. 

(

See Fig. 6-4

)

Re-install the air filter.

Install and close the air-in grill in the reverse order of step 1 
and  2  and  connect  the  control  box  cables  to  the 
corresponding terminators of the main body .    

5

6

Fig.6-1

Fig.6-2

Fig.6-3

Fig.6-4

Do not dry out the air filter under direct sunshine or with 
fire.

CAUTION

Maintenance after a long stop period 

(eg. at the beginning of the season)

 

Maintenance before a long stop period

 

(eg. at the end of the season)

         

Check  and  remove  everything  that  might  be  blocking  inlet 
and outlet vents of indoor units and outdoor units.

Clean air filters and casings of indoor units. 
Refer to "Cleaning the air filter" for details on how  to proceed 
and make  sure to install  cleaned  air filters back  in the  same 
position. 

Turn on the power at least 12 hours before operating the unit 
in order to ensure smoother operation. As soon as he power 
is turned on, the remote controller  displays appear.

Let the indoor units run in fan only operation for about half a 
day in order to dry the interior of the units.

Clean  air  filters  and  casings  of  indoor  units.  Refer  to  " 
Cleaning  the  air  filter"  for  details  on  how  to  proceed  and 
make  sure  to  install  cleaned  air  filters  back  in  the  same 
position. 

Содержание MCD-48HRFN1-Q

Страница 1: ...Four way Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference...

Страница 2: ......

Страница 3: ...de air in grill Air inlet Air inlet Air inlet Air outlet 3 9 10 10 11 11 11 11 11 11 12 12 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the a...

Страница 4: ...al waste use separate collection facilities Contact you local government for information regarding the connection systems available If electrical appliances are disposed of in landfills or dumps hazar...

Страница 5: ...e Cleaning and user maintenance shall not be made by children without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilit...

Страница 6: ...ailing to do so may cause static or distorted pictures A dirty air filter will reduce cooling or heating efficiency please clean it once two weeks While the unit is in operation you can adjust the air...

Страница 7: ...filter shown in Fig 6 1 Pull the air in grill down at 45 and lift it up to take out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air fi...

Страница 8: ...tem does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 2 8 1 Troubles...

Страница 9: ...ck flash Quick flash Lifting panel communication checking channel is abnormal Collision model malfunction E0 Quick flash 14 Table 8 1b Applicable to fixed frequency air conditioner only NO Malfunction...

Страница 10: ...etely closed Leakage of refrigerant or lack of refrigerant Table 8 2 Find reasons and solution Symptoms Causes The fan speed can not be changed Check whether the MODE indicated on the display is AUTO...

Страница 11: ...QS01U 019AW 202000171396 20131211 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 12: ......

Отзывы: