background image

  Page 14  

Ins

tallation

Ins

tructions

Window Requiri

m

ents

Do the following before beginning installation. 
See illustrations below. Check dimensions of 
your unit to determine model type:

Model type:  

15k/18k 

25k

Unit Height:  

17-5/8” 

18-5/8”

Unit Width: 

23-5/8” 

26-1/2”

Min. Window Opening: 

18-1/2” 

19-1/2”

Min. Window Width: 

26-1/2” 

31”

Max. Window Width: 

40-1/2” 

42”

Preli

m

inary Instructions

Window Sash Seal

Top Rail

Foam Gasket

3/4” Long Flat Head Bolt

Sill Angle Bracket

1 /2” Long
Screw and
Locknuts

Window 
Support
Bracket

Frame
Assembly
(Right)

Side
Retainer

Washer Head
Locking
Screw

Bottom Rail
Seal to Unit

Frame
Assembly
(Left)

Safety Lock and 
3/4” (or 1/2” ) Long 
Hex Head Screw

Locknuts

Read these instructions co

m

pletely 

and carefully.

• IMPORTANT

 - Save these 

instructions for local inspector’s use.

• IMPORTANT

 - Observe all 

governing codes and ordinances.

•  Note to Installer - Be sure to 

leave these instructions with the 
consu

m

er.

•  Note to Consu

m

er - Keep these 

instructions for future reference.

•  Skill level - Installation of 

this appliance requires basic 

m

echanical skills.

• Co

m

pletion ti

m

e - Approxi

m

ately 

1 hour.

We reco

mm

end that two people 

install this product.

Proper installation is the 
responsibility of the installer.

Product failure due to i

m

proper 

installation is not covered under the 
Warranty.

You MUST use all supplied parts and 
use proper installation procedures as 
described in these instructions when 
installing this air conditioner.

Do not, under any circu

m

stances, cut 

or re

m

ove the third (ground) prong 

fro

m

 the power cord.

Do not change the plug on the power 
cord of the air conditioner.

Alu

m

inu

m

 house wiring 

m

ay present 

special proble

m

s - consult a qualified 

electrician.

When handling unit, be careful to 
avoid cuts fro

m

 sharp 

m

etal edges 

and alu

m

inu

m

 fins on front and 

rear coils.

WARNING - Before You Begin

Save carton and these Installation 
Instructions for future reference. The carton 
is the best way to store unit during winter, 
or when not in use.

NOTE

2

Installation Instructions

Содержание MAW15R1YWT

Страница 1: ...is product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with your dealer...

Страница 2: ...an authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm per...

Страница 3: ...shock Unplug the unit if you notice unusual sounds or smells or smoke coming from it A damaged product may cause fire and electric shock Ventilate room before operating the air conditioner if there i...

Страница 4: ...quate ventilation may limit the product useful life Use a cloth with mild soap and water solution to clean the appliance do not use harsh cleaners or chemicals Always disconnect the unit from the powe...

Страница 5: ...are that refrigerants may not contain an odor Keep ventilation openings clear of obstruction Store the appliance in a way that will prevent mechanical damage from occurring Store the appliance in a we...

Страница 6: ...ircuit breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not run air conditioner without outside protective cover in...

Страница 7: ...on the side of the cabinet and behind the grille If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track typ...

Страница 8: ...HYDSRUDWRU GXULQJ QRUPDO RSHUDWLRQ Sound of Rushing Air Q IURQW RI WKH XQLW RX PD KHDU WKH VRXQG RI UXVKLQJ DLU EHLQJ PRYHG E WKH IDQ To reduce the risk of fire electrical shock personal injury or pro...

Страница 9: ...C Indoor temp 32 80 F 0 27 C Before you begin thoroughly familiarize yourself with the control panel as shown below and all its functions then follow the symbol for the functions you desire The unit c...

Страница 10: ...ncrease by 2 F 1 or 2 C 30 minutes after the mode is selected The temperature will then increase by another 2 F 1 or 2 C after an additional 30 minutes This new temperature will be maintained for 6 ho...

Страница 11: ...o Fan modes To operate on Auto feature When you set the air conditioner to AUTO mode it will automatically select cooling or fan only operation depending on what temperature you have selected and the...

Страница 12: ...st press the Timer button The TIMER ON indicator light will illuminate indicating the Auto Start program has initiated When the time of TIMER ON is displayed press the Timer button again The TIMER OFF...

Страница 13: ...breaker tripping The fan will continue to run during this time The control can display temperature in Fahrenheit or Celsius To convert from one to the other press and hold the UP DOWN buttons at the...

Страница 14: ...ons with the consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion time Approximately 1 hour We...

Страница 15: ...such as shrubs trees or awnings Inside be sure furniture drapes or blinds will not stop proper airflow 4 Check the available electrical service Power supply must be the same as that shown on the unit...

Страница 16: ...side by the base if installed 7 Hold the cabinet while pulling on the base handle and carefully remove the unit 8 Add two foam inserts to holes in top of cabinet where shipping screws were removed fr...

Страница 17: ...ccordion panel frame into channel in the top rail and bottom rail Do both sides 4 Insert washer head locking screws 2 into holes in top leg of accordion panel frame see step 6 Do not completely tighte...

Страница 18: ...s 5 Add bottom rail seal over screws to window sill Fig 25 Bottom Rail Seal 3 4 or 1 2 Long Hex head Screw Fig 27 Right Left Locknut Sill Angle Bracket Flathead Bolt 2 Each Required For Each Support B...

Страница 19: ...y lock Fig 31 8 Install Chassis into Cabinet and Install Front to Unit 1 Lift air conditioner and carefully slide into cabinet leaving 6 152mm protruding 2 DO NOT press or apply pressure to controls o...

Страница 20: ...nt may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleansers wax or...

Страница 21: ...warm ice forming on cooling coil behind decorative front Outdoor temperature below 64 F 18 C To defrost the coil set to FAN ONLY mode Air filter may be dirty Clean filter Refer to Care and Cleaning s...

Страница 22: ...sively humid days Remote sensing deactivating prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control sig...

Страница 23: ...r materials block the signals from the remote controller to the unit Prevent any liquid from spilling onto the remote controller Do not expose the remote controller to direct sunlight or heat If the i...

Страница 24: ...ased on typical model and may vary slightly from the actual one you purchased All the functions described are accomplished by the unit If the unit is without a feature the unit will not respond if the...

Страница 25: ...f the unit display lights Pressing this button again will turn the display lights back on Pressing any button on the unit or remote while the display is off will activate the lights for three seconds...

Страница 26: ...er 2 Press the MODE button to select Cool or Fan mode 3 Press the TEMP UP DOWN button to set the desired temperature 4 Press the FAN UP DOWN button to select the fan speed NOTE Temperature cannot be c...

Страница 27: ...is initiated When the TIMER OFF indicator is displayed on the LED window of the air conditioner it indicates the Auto Stop setting program is initiated 2 Press or hold the TEMP UP DOWN to change the A...

Страница 28: ...ED display of the unit 4 Use the TEMP UP DOWN button to display 10 on the LED display of the unit 5 Wait for 5 seconds until the previous display appears in LED window AUTO START AUTO STOP Off Start S...

Страница 29: ...of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment to an outlet on a circuit different from th...

Страница 30: ......

Отзывы: