4. TROUBLE SHOOTING
4.1 Test mode by Control
Note: Before entering the test mode, you should empty the machine so that there is no
water left in the tub. You can run a Spin Only cycle or operate as following steps to get all
water out. Then make sure all parts are in their original position for check running.
Step 1
:
Lay the drain hose down to insert the end of the hose into an
outfall on floor.
Step 2: Remove the Back Panel from the unit.
Step 3: Find the Drain Valve and pull the bar and keep pulling as the
arrow direction as right figure.
Step 4: Wait for the water to be drained out.
Now, the unit is ready for test check.